Demonstration of full 4×4 Mueller polarimetry through an optical fiber for endoscopic applications.

Sandeep Manhas, Jérémy Vizet, Stanislas Deby, Jean-Charles Vanel, Paola Boito, Mireille Verdier, Antonello De Martino, Dominique Pagnoux.   

Abstract

A novel technique to measure the full 4 × 4 Mueller matrix of a sample through an optical fiber is proposed, opening the way for endoscopic applications of Mueller polarimetry for biomedical diagnosis. The technique is based on two subsequent Mueller matrices measurements: one for characterizing the fiber only, and another for the assembly of fiber and sample. From this differential measurement, we proved theoretically that the polarimetric properties of the sample can be deduced. The proof of principle was experimentally validated by measuring various polarimetric parameters of known optical components. Images of manufactured and biological samples acquired by using this approach are also presented.

Year:  2015        PMID: 25836165     DOI: 10.1364/OE.23.003047

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  5 in total

1.  A high definition Mueller polarimetric endoscope for tissue characterisation.

Authors:  Ji Qi; Daniel S Elson
Journal:  Sci Rep       Date:  2016-05-12       Impact factor: 4.379

2.  Polarization image segmentation of radiofrequency ablated porcine myocardial tissue.

Authors:  Iftikhar Ahmad; Adam Gribble; Iqbal Murtza; Masroor Ikram; Mihaela Pop; Alex Vitkin
Journal:  PLoS One       Date:  2017-04-05       Impact factor: 3.240

3.  In vivo imaging of uterine cervix with a Mueller polarimetric colposcope.

Authors:  Jérémy Vizet; Jean Rehbinder; Stanislas Deby; Stéphane Roussel; André Nazac; Ranya Soufan; Catherine Genestie; Christine Haie-Meder; Hervé Fernandez; François Moreau; Angelo Pierangelo
Journal:  Sci Rep       Date:  2017-06-01       Impact factor: 4.379

4.  Depolarizing metrics for plant samples imaging.

Authors:  Albert Van Eeckhout; Enric Garcia-Caurel; Teresa Garnatje; Mercè Durfort; Juan Carlos Escalera; Josep Vidal; José J Gil; Juan Campos; Angel Lizana
Journal:  PLoS One       Date:  2019-03-14       Impact factor: 3.240

5.  3D Mueller matrix mapping of layered distributions of depolarisation degree for analysis of prostate adenoma and carcinoma diffuse tissues.

Authors:  Volodymyr A Ushenko; Benjamin T Hogan; Alexander Dubolazov; Gennadii Piavchenko; Sergey L Kuznetsov; Alexander G Ushenko; Yuriy O Ushenko; Mykhailo Gorsky; Alexander Bykov; Igor Meglinski
Journal:  Sci Rep       Date:  2021-03-04       Impact factor: 4.379

  5 in total