Literature DB >> 25832964

Validity of activity monitors worn at multiple nontraditional locations under controlled and free-living conditions in young adult women.

Hideaki Kumahara1, Makoto Ayabe, Misato Ichibakase, Akari Tashima, Maiko Chiwata, Tomomi Takashi.   

Abstract

The purpose of this study was to examine the validity of counting steps and computing indices of moderate-to-vigorous physical activity (MVPA) using miniature activity monitors with 3-D technology worn at various locations under controlled (CON) and free-living conditions (FL). Kenz e-style2, Tanita Calorism Smart, and Omron Calori Scan HJA-306 activity monitors were assessed. Nine and 31 young adult women were assigned to the CON and FL studies, respectively. While walking or jogging on a treadmill at 5 different speeds, the subjects simultaneously carried the 3 different monitors in a pants pocket (PP), a chest shirt pocket, and a shoulder bag (B). Under the FL condition, the 3 monitors were placed only at the PP and B locations for practical reasons. Significant effects of monitor location and walking/jogging speed on the step count measured by the 3 monitors were evaluated under the CON condition. Monitors placed at both PP and B tended to underestimate the number of steps; however, there were no significant differences between the values obtained with the Kenz monitor and those obtained with a criterion accelerometer under the FL condition. Moreover, strong correlations were observed between steps measured by monitors placed at PP and steps measured by the criterion accelerometer. The amount of MVPA for the PP location and the non-carrying duration of the bag for the B location were considered to be important determinants of the accuracy of step counting under the FL condition. In conclusion, monitors placed at the PP location, especially the Kenz monitor, showed acceptable accuracy for young adult women in real-life settings. In contrast, MVPA indices assessed using these monitors showed limited validity.

Entities:  

Keywords:  Japanese; Japonais; accelerometer; accéléromètre; activité physique; exercise intensity; intensité d’exercice; locomotion; pedometer; physical activity; podomètre

Mesh:

Year:  2015        PMID: 25832964     DOI: 10.1139/apnm-2014-0183

Source DB:  PubMed          Journal:  Appl Physiol Nutr Metab        ISSN: 1715-5312            Impact factor:   2.665


  4 in total

1.  The validity of activity trackers is affected by walking speed: the criterion validity of Garmin Vivosmart® HR and StepWatch 3 for measuring steps at various walking speeds under controlled conditions.

Authors:  Frederik Rose Svarre; Mads Møller Jensen; Josephine Nielsen; Morten Villumsen
Journal:  PeerJ       Date:  2020-07-14       Impact factor: 2.984

Review 2.  Toward Harmonized Treadmill-Based Validation of Step-Counting Wearable Technologies: A Scoping Review.

Authors:  Christopher C Moore; Aston K McCullough; Elroy J Aguiar; Scott W Ducharme; Catrine Tudor-Locke
Journal:  J Phys Act Health       Date:  2020-07-11

3.  Predictors of Achieving Recommended Daily Physical Activity Among Anesthesiologists at a Large Tertiary Care Academic Center.

Authors:  Vesela P Kovacheva; Lawrence C Tsen
Journal:  J Clin Med Res       Date:  2017-12-01

Review 4.  Quality Evaluation of Free-living Validation Studies for the Assessment of 24-Hour Physical Behavior in Adults via Wearables: Systematic Review.

Authors:  Marco Giurgiu; Irina Timm; Marlissa Becker; Steffen Schmidt; Kathrin Wunsch; Rebecca Nissen; Denis Davidovski; Johannes B J Bussmann; Claudio R Nigg; Markus Reichert; Ulrich W Ebner-Priemer; Alexander Woll; Birte von Haaren-Mack
Journal:  JMIR Mhealth Uhealth       Date:  2022-06-09       Impact factor: 4.947

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.