Literature DB >> 25832041

GPU-accelerated regularized iterative reconstruction for few-view cone beam CT.

Dmitri Matenine1, Yves Goussard2, Philippe Després3.   

Abstract

PURPOSE: The present work proposes an iterative reconstruction technique designed for x-ray transmission computed tomography (CT). The main objective is to provide a model-based solution to the cone-beam CT reconstruction problem, yielding accurate low-dose images via few-views acquisitions in clinically acceptable time frames.
METHODS: The proposed technique combines a modified ordered subsets convex (OSC) algorithm and the total variation minimization (TV) regularization technique and is called OSC-TV. The number of subsets of each OSC iteration follows a reduction pattern in order to ensure the best performance of the regularization method. Considering the high computational cost of the algorithm, it is implemented on a graphics processing unit, using parallelization to accelerate computations.
RESULTS: The reconstructions were performed on computer-simulated as well as human pelvic cone-beam CT projection data and image quality was assessed. In terms of convergence and image quality, OSC-TV performs well in reconstruction of low-dose cone-beam CT data obtained via a few-view acquisition protocol. It compares favorably to the few-view TV-regularized projections onto convex sets (POCS-TV) algorithm. It also appears to be a viable alternative to full-dataset filtered backprojection. Execution times are of 1-2 min and are compatible with the typical clinical workflow for nonreal-time applications.
CONCLUSIONS: Considering the image quality and execution times, this method may be useful for reconstruction of low-dose clinical acquisitions. It may be of particular benefit to patients who undergo multiple acquisitions by reducing the overall imaging radiation dose and associated risks.

Entities:  

Mesh:

Year:  2015        PMID: 25832041     DOI: 10.1118/1.4914143

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  A distributed ASTRA toolbox.

Authors:  Willem Jan Palenstijn; Jeroen Bédorf; Jan Sijbers; K Joost Batenburg
Journal:  Adv Struct Chem Imaging       Date:  2016-12-07

2.  Enabling tomography with low-cost C-arm systems.

Authors:  Monica Abella; Claudia de Molina; Nerea Ballesteros; Alba García-Santos; Álvaro Martínez; Inés García; Manuel Desco
Journal:  PLoS One       Date:  2018-09-13       Impact factor: 3.240

3.  Three-Dimensional Dosimetry by Optical-CT and Radiochromic Gel Dosimeter of a Multiple Isocenter Craniospinal Radiation Therapy Procedure.

Authors:  Matheus Antonio da Silveira; Juliana Fernandes Pavoni; Alexandre Colello Bruno; Gustavo Viani Arruda; Oswaldo Baffa
Journal:  Gels       Date:  2022-09-13

4.  Accelerating an Ordered-Subset Low-Dose X-Ray Cone Beam Computed Tomography Image Reconstruction with a Power Factor and Total Variation Minimization.

Authors:  Hsuan-Ming Huang; Ing-Tsung Hsiao
Journal:  PLoS One       Date:  2016-04-13       Impact factor: 3.240

5.  GPU-accelerated iterative reconstruction for limited-data tomography in CBCT systems.

Authors:  Claudia de Molina; Estefania Serrano; Javier Garcia-Blas; Jesus Carretero; Manuel Desco; Monica Abella
Journal:  BMC Bioinformatics       Date:  2018-05-15       Impact factor: 3.169

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.