Literature DB >> 25827970

Test-retest reliability and responsiveness of centre of pressure measurements in patients with hip osteoarthritis.

D Laroche1, A Kubicki2, P J Stapley3, V Gremeaux4, K Mazalovic5, J-F Maillefert6, P Ornetti6.   

Abstract

OBJECTIVE: The aim of this study was to determine a set of measures for the evaluation of balance in patients suffering from hip osteoarthritis (OA) that were both reliable and responsive to change.
DESIGN: Three groups of subjects; Healthy, hip OA patients without surgery, and hip OA with surgery (pre and post-surgery) were included in this study. Subjects had to perform balance tests in two positions: standard and narrowed stance. CoP-based measures test-retest reliability was assessed in hip OA without surgery group, responsiveness were assessed between all groups and between pre and post-surgery.
RESULTS: Intraclass Correlation Coefficient (ICC) values from hip OA without surgery ranged from -0.03 to 0.9 for only five parameters (CoP path length, SD velocity, mean velocity, and antero-posterior Root Mean Square (RMS(AP)) having values over 0.7. SD velocity and RMS(AP) showed significant differences between healthy and surgery group in standard stance whereas narrowed stance revealed most differences between all groups. RMS(AP) showed the best responsiveness (Standardized Response Mean ∼0.5) between pre vs post-surgery in both conditions. RMS(AP) was also capable of discriminating between hip OA with surgery vs without surgery groups with good sensitivity and specificity.
CONCLUSIONS: Our results showed there to be reliability and responsiveness of five postural parameters in hip OA patients in two conditions of standing balance. More parameters were significantly different in narrowed stance whereas sensitivity was better in standard stance. SD velocity and RMS(AP) discriminate between degrees of OA severity and highlight potential balance deficits even after arthroplasty. Selected parameters during standing balance could be assessed to complete the set of quantitative measures to quantify hip OA patient deficiencies.
Copyright © 2015 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Hip; Osteoarthritis; Reliability; Responsiveness; Standing balance

Mesh:

Year:  2015        PMID: 25827970     DOI: 10.1016/j.joca.2015.03.029

Source DB:  PubMed          Journal:  Osteoarthritis Cartilage        ISSN: 1063-4584            Impact factor:   6.576


  3 in total

1.  Clinician's Commentary on Akhbari et al.(1).

Authors:  Karl Zabjek
Journal:  Physiother Can       Date:  2015-08       Impact factor: 1.037

2.  A comparison of two techniques for center of pressure measurements.

Authors:  Jessica DeBerardinis; Conner Neilsen; Daniel E Lidstone; Janet S Dufek; Mohamed B Trabia
Journal:  J Rehabil Assist Technol Eng       Date:  2020-07-06

3.  Reliability analysis of a sensitive and independent stabilometry parameter set.

Authors:  Gergely Nagymáté; Zsanett Orlovits; Rita M Kiss
Journal:  PLoS One       Date:  2018-04-17       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.