A new system to produce intraoperatively custom femoral prosthesis from measurements taken during the surgical procedure.

J C Mulier1, M Mulier, L P Brady, H Steenhoudt, Y Cauwe, M Goossens, M Elloy.   

Abstract

A system has been developed that allows the surgeon to match a prosthesis to any femoral cavity. The surgeon may choose how and where it will preferentially fit. The surgeon does not have to create a cavity to suit a premade prosthesis. The system is based on a novel technique for making a mold of the prepared femoral cavity. This is accurately and thoroughly measured using a laser. An implant is designed and manufactured while the operation is in progress using state-of-the-art computer and machining techniques. All important parameters such as neck length, offset, and anteversion are fully variable intraoperatively. To date, more than 800 consecutive procedures have been carried out. In a limited trial, no subjective difference was found with a cemented Charnley total hip arthroplasty at one year. It currently takes about 40 minutes to manufacture the implant and make it available in the operating room, and this time is being continually reduced. Using a femur first approach, operating time is not greatly extended. In the future, perhaps the operating time will not be extended at all. All data including cavity geometry are centrally recorded for analysis.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2582680

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  4 in total

1.  Basic science considerations in primary total hip replacement arthroplasty.

Authors:  Saqeb B Mirza; Douglas G Dunlop; Sukhmeet S Panesar; Syed G Naqvi; Shafat Gangoo; Saif Salih
Journal:  Open Orthop J       Date:  2010-05-11

2.  Uncemented custom femoral components in hip arthroplasty. A prospective clinical study of 191 hips followed for at least 7 years.

Authors:  Pål Benum; Arild Aamodt
Journal:  Acta Orthop       Date:  2010-08       Impact factor: 3.717

3.  In vivo evaluation of a vibration analysis technique for the per-operative monitoring of the fixation of hip prostheses.

Authors:  Leonard C Pastrav; Siegfried Vn Jaecques; Ilse Jonkers; Georges Van der Perre; Michiel Mulier
Journal:  J Orthop Surg Res       Date:  2009-04-09       Impact factor: 2.359

4.  RAPID MANUFACTURING SYSTEM OF ORTHOPEDIC IMPLANTS.

Authors:  Carlos Relvas; Joana Reis; José Alberto Caeiro Potes; Fernando Manuel Ferreira Fonseca; José Antonio Oliveira Simões
Journal:  Rev Bras Ortop       Date:  2015-11-16
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.