Literature DB >> 25826271

Radiological protection evaluation of the Bucharest Tandetron 3 MV accelerator.

I O Mitu1, G Floare, D G Ghiţă, D V Moşu, Gh Căta-Danil.   

Abstract

Low energy heavy charged particle accelerators are generators of ionizing radiation, due to the ion beam interactions into the machine components, targets and surrounding materials. Nowadays there are available computational tools allowing realistic estimates of radiation doses and residual activity of the activated components. These evaluations are further used to design the radiological safety system required by licensing and operation of the equipment.This paper presents results of measurements and numerical simulations of the radiation doses and residual activity, at the recently commissioned Bucharest 3 MV Cockcroft-Walton type Tandetron accelerator presently used mainly for Ion Beam Analysis (IBA) research.

Entities:  

Mesh:

Year:  2015        PMID: 25826271     DOI: 10.1088/0952-4746/35/2/285

Source DB:  PubMed          Journal:  J Radiol Prot        ISSN: 0952-4746            Impact factor:   1.394


  1 in total

1.  Superintense Laser-driven Ion Beam Analysis.

Authors:  M Passoni; L Fedeli; F Mirani
Journal:  Sci Rep       Date:  2019-06-24       Impact factor: 4.379

  1 in total