Literature DB >> 25826045

Routine EPID in-vivo dosimetry in a reference point for conformal radiotherapy treatments.

Andrea Fidanzio1, Luigi Azario, Francesca Greco, Savino Cilla, Angelo Piermattei.   

Abstract

In-vivo dosimetry (IVD) in external beam radiotherapy is used to detect major clinically relevant differences between planned and delivered dose. Moreover, a detailed analysis of its results, when routinely reported and discussed by the radiotherapy staff, can limit the likelihood of error transmission to many treatments. A first experience of routine EPID-based IVD in a reference point has been performed in our department for 3D-CRT treatments over a three-year period. More than 14,000 images were acquired and 1287 treatment plans were verified. The IVD checks were obtained three times in the first week and then weekly. Tolerance levels of ± 5% for pelvic-abdomen, head-neck and breast irradiations and ± 6% for lung treatments were adopted for the in-vivo measured dose per fraction. A statistical analysis of the IVD results was performed grouping the data by: anatomical regions, treatment units, open and wedged fields and gantry angles. About 10% of the checked doses per fraction showed dosimetric discrepancies out of the tolerance levels. The causes of the discrepancies were 70% delivery or planning errors, 20% morphological changes and 10% procedural limitations. 41 cases (3.2%) have required special investigations because their in-vivo doses per fraction, averaged over the first three sessions, were out of the tolerance levels and in 19 cases (1.5%) the deviations gave rise to an intervention. Statistically significant differences of average variations between planned and delivered doses were observed for: (i) 30° wedged 10 MV fields with respect to those of other wedged or open 10 MV fields delivered by two linacs, due to the incorrect TPS implementation of that wedge transmission factor; (ii) anterior-posterior and posterior-anterior beams with respect to the other gantry orientations for one linac, due to the beam attenuation introduced by the treatment couch; (iii) lateral fields with respect to medial fields of breast irradiations for all linacs, due to small systematic set-up variations. The analysis of our data shows a substantial homogeneity of the IVD results for all the considered body regions and treatment units. However, the observed discrepancies have supplied indications for taking further steps in the optimization process and in some cases to adopt an adaptive approach.

Entities:  

Mesh:

Year:  2015        PMID: 25826045     DOI: 10.1088/0031-9155/60/8/N141

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Improved error detection using a divided treatment plan in volume modulated arc therapy.

Authors:  Kazuo Tarutani; Masao Tanooka; Hiroshi Doi; Masayuki Fujiwara; Masaki Miyashita; Kazufumi Kagawa; Norihiko Kamikonya; Koichiro Yamakado
Journal:  Rep Pract Oncol Radiother       Date:  2019-01-21

2.  In vivo Portal Imaging Dosimetry Identifies Delivery Errors in Rectal Cancer Radiotherapy on the Belly Board Device.

Authors:  Stefano Peca; Richie Siddhartha Sinha; Derek Wilson Brown; Wendy Lani Smith
Journal:  Technol Cancer Res Treat       Date:  2017-06-06

3.  Feasibility of portal dosimetry for flattening filter-free radiotherapy.

Authors:  Robert W Chuter; Philip A Rixham; Steve J Weston; Vivian P Cosgrove
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

4.  A Feasibility Study for in vivo Dosimetry Procedure in Routine Clinical Practice.

Authors:  Maria D Falco; Stefano Giancaterino; Andrea De Nicola; Nico Adorante; Ramon Gimenez De Lorenzo; Monica Di Tommaso; Annamaria Vinciguerra; Marianna Trignani; Francesca Perrotti; Albina Allajbej; Andrea Fidanzio; Francesca Greco; Mattia Grusio; Domenico Genovesi; Angelo Piermattei
Journal:  Technol Cancer Res Treat       Date:  2018-01-01

5.  EPID based in vivo dosimetry system: clinical experience and results.

Authors:  Sofia Celi; Emilie Costa; Claas Wessels; Alejandro Mazal; Alain Fourquet; Pascal Francois
Journal:  J Appl Clin Med Phys       Date:  2016-05-08       Impact factor: 2.102

Review 6.  In vivo dosimetry in external beam photon radiotherapy: Requirements and future directions for research, development, and clinical practice.

Authors:  Igor Olaciregui-Ruiz; Sam Beddar; Peter Greer; Nuria Jornet; Boyd McCurdy; Gabriel Paiva-Fonseca; Ben Mijnheer; Frank Verhaegen
Journal:  Phys Imaging Radiat Oncol       Date:  2020-08-29
  6 in total