Literature DB >> 25822305

Reliability of the impression replica technique.

Anders Falk, Per Vult von Steyern, Håkan Fransson, Margareta Molin Thorén.   

Abstract

The aim of this study was to evaluate the reliability of the impression replica technique with a four-unit zirconia fixed dental prosthesis (FDP). Marginal and internal fit were measured by repeatedly placing the FDP on an epoxy cast using light-body silicone material corresponding to cement. All measured marginal and internal fit points showed varying values. The greatest variations were seen at the most distal margin (33 μm) and at the distal abutment of the FDP (77 μm). The results showed that the technique gives moderate variations and is a useful method to evaluate marginal and internal fit.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25822305     DOI: 10.11607/ijp.4132

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  8 in total

1.  Comparison of the fit accuracy of zirconia-based prostheses generated by two CAD/CAM systems.

Authors:  Seok-Joon Ha; Jin-Hyun Cho
Journal:  J Adv Prosthodont       Date:  2016-12-15       Impact factor: 1.904

2.  Verification of a computer-aided replica technique for evaluating prosthesis adaptation using statistical agreement analysis.

Authors:  Hang-Nga Mai; Kyeong Eun Lee; Kyu-Bok Lee; Seung-Mi Jeong; Seok-Jae Lee; Cheong-Hee Lee; Seo-Young An; Du-Hyeong Lee
Journal:  J Adv Prosthodont       Date:  2017-10-16       Impact factor: 1.904

3.  Marginal accuracy of computer-aided design- and computer-aided manufacturing-fabricated full-arch zirconia restoration.

Authors:  Niwut Juntavee; Issarawas Sirisathit
Journal:  Clin Cosmet Investig Dent       Date:  2018-02-15

4.  Comparison of three-dimensional digital technique with two-dimensional replica method for measuring marginal and internal fit of full coverage restorations.

Authors:  Mahya Hasanzade; Soudabeh Koulivand; Naeime Moslemian; Marzieh Alikhasi
Journal:  J Adv Prosthodont       Date:  2020-06-18       Impact factor: 1.904

5.  Evaluation of the effect of dentin surface treatment by air abrasion and Er:YAG laser on the retention of metal crowns luted with glass ionomer cement in teeth with reduced crown height: An in vitro study.

Authors:  Sameer Chauhan; Neerja Mahajan; Rajesh Sethuraman; Y G Naveen
Journal:  J Indian Prosthodont Soc       Date:  2019 Apr-Jun

Review 6.  A systematic review on the accuracy of zirconia crowns and fixed dental prostheses.

Authors:  Per Svanborg
Journal:  Biomater Investig Dent       Date:  2020-01-07

7.  In vitro validation of Digital Image Analysis Sequence (DIAS) for the assessment of the marginal fit of cement-retained implant-supported experimental crowns.

Authors:  Aristeidis A Villias; Stefanos G Kourtis; Hercules C Karkazis; Gregory L Polyzois
Journal:  Int J Implant Dent       Date:  2021-02-15

Review 8.  A systematic review on the accuracy of manufacturing techniques for cobalt chromium fixed dental prostheses.

Authors:  Per Svanborg; Lars Hjalmarsson
Journal:  Biomater Investig Dent       Date:  2020-01-20
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.