Literature DB >> 25822300

Zirconia-based crowns up to 5 years in function: a retrospective clinical study and evaluation of prosthetic restorations and failures.

M Barιş Güncü, Umut Cakan, Mehmet Muhtarogullari, Senay Canay.   

Abstract

PURPOSE: The purpose of this retrospective study was to evaluate the 5-year clinical performance and failure rate of single- or multiple-unit zirconia-based crowns.
MATERIALS AND METHODS: A total of 148 patients (39 men and 109 women, mean age: 46.9 ± 10.6 years) treated in university and private practices with 618 single- or multiple-unit zirconia-based (Lava) crowns made on natural teeth from January 2007 to December 2008 were included. Two hundred fifty-nine anterior and 359 posterior crowns were examined. A core and/or veneer fracture that required replacement of the restoration was considered to be a failure. The cumulative survival rate (CSR) was described with Kaplan-Meier survival functions. The crowns replaced for other reasons were deemed lost to follow-up, and esthetic, functional, and biologic complications were rated.
RESULTS: At the 5-year follow-up, no zirconia core fractures were observed. Twelve veneer fractures that required crown replacement were detected. The CSR was 98.1%. There was a statistically significant difference between survival of the anterior and posterior restorations (P < .001). In total, 116 crowns experienced biologic and technical complications. The most common complications were smooth veneer fracture (4, 0.6%), loss of retention (7, 1%), staining because of smoking (24, 4%), and gingival recession (48, 8%).
CONCLUSIONS: According to the 5-year CSR (98.1%) observed in this study, zirconia-based single or multiple crowns may be considered an acceptable treatment modality for the replacement of anterior and posterior teeth. RESULTS from the current study should be supported by additional randomized clinical trials.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25822300     DOI: 10.11607/ijp.4168

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  8 in total

1.  Clinical evaluation of zirconia-based all-ceramic single crowns: an up to 12-year retrospective cohort study.

Authors:  Shoko Miura; Shin Kasahara; Shinobu Yamauchi; Yayoi Okuyama; Akio Izumida; Jun Aida; Hiroshi Egusa
Journal:  Clin Oral Investig       Date:  2017-06-12       Impact factor: 3.573

2.  Remake Rates for Single-Unit Crowns in Clinical Practice: Findings from The National Dental Practice-Based Research Network.

Authors:  Michael S McCracken; Mark S Litaker; Valeria V Gordan; Thomas Karr; Ellen Sowell; Gregg H Gilbert
Journal:  J Prosthodont       Date:  2018-11-22       Impact factor: 2.752

Review 3.  Evaluation of success rate of Zirconia based restorations: A systematic review.

Authors:  Aditee Apte; Seema Sathe; Rewa Kawade
Journal:  J Clin Exp Dent       Date:  2022-09-01

4.  Evaluation of zirconia-porcelain interface using X-ray diffraction.

Authors:  Tariq F Alghazzawi; Gregg M Janowski
Journal:  Int J Oral Sci       Date:  2015-09-14       Impact factor: 6.344

5.  Load-bearing capacity of various CAD/CAM monolithic molar crowns under recommended occlusal thickness and reduced occlusal thickness conditions.

Authors:  Sulki Choi; Hyung-In Yoon; Eun-Jin Park
Journal:  J Adv Prosthodont       Date:  2017-12-14       Impact factor: 1.904

6.  A Three-Year Retrospective Study on Survival of Ceramic-Veneered Zirconia (Y-TZP) Fixed Dental Prostheses Performed in Private Practices.

Authors:  Veronika Norström Saarva; Göran Bjerkstig; Anders Örtorp; Per Svanborg
Journal:  Int J Dent       Date:  2017-06-20

7.  Fracture of Lithia Disilicate Ceramics under Different Environmental Conditions.

Authors:  Josephine F Esquivel-Upshaw; Shu-Min Hsu; Fan Ren; Jenna Stephany; Xinyi Xia; Chan-Wen Chiu; Dan Neal; John J Mecholsky
Journal:  Materials (Basel)       Date:  2022-07-29       Impact factor: 3.748

8.  Load-Bearing Capacity of Zirconia Crowns Screwed to Multi-Unit Abutments with and without a Titanium Base: An In Vitro Pilot Study.

Authors:  Hadas Heller; Adi Arieli; Ilan Beitlitum; Raphael Pilo; Shifra Levartovsky
Journal:  Materials (Basel)       Date:  2019-09-20       Impact factor: 3.623

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.