Literature DB >> 25820341

The transverse diameter of the chest on routine radiographs reliably estimates gestational age and weight in premature infants.

Kelly R Dietz1, Lei Zhang, Frank G Seidel.   

Abstract

BACKGROUND: Prior to digital radiography it was possible for a radiologist to easily estimate the size of a patient on an analog film. Because variable magnification may be applied at the time of processing an image, it is now more difficult to visually estimate an infant's size on the monitor. Since gestational age and weight significantly impact the differential diagnosis of neonatal diseases and determine the expected size of kidneys or appearance of the brain by MRI or US, this information is useful to a pediatric radiologist. Although this information may be present in the electronic medical record, it is frequently not readily available to the pediatric radiologist at the time of image interpretation.
OBJECTIVE: To determine if there was a correlation between gestational age and weight of a premature infant with their transverse chest diameter (rib to rib) on admission chest radiographs.
MATERIALS AND METHODS: This retrospective study was approved by the institutional review board, which waived informed consent. The maximum transverse chest diameter outer rib to outer rib was measured on admission portable chest radiographs of 464 patients admitted to the neonatal intensive care unit (NICU) during the 2010 calendar year. Regression analysis was used to investigate the association between chest diameter and gestational age/birth weight. Quadratic term of chest diameter was used in the regression model.
RESULTS: Chest diameter was statistically significantly associated with both gestational age (P < 0.0001) and birth weight (P < 0.0001).
CONCLUSION: An infant's gestational age and birth weight can be reliably estimated by comparing a simple measurement of the transverse chest diameter on digital chest radiograph with the tables and graphs in our study.

Entities:  

Mesh:

Year:  2015        PMID: 25820341     DOI: 10.1007/s00247-015-3332-x

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  6 in total

1.  Measurement of thoracic spine length on chest radiographs of newborn infants.

Authors:  L R Kuhns; J F Holt
Journal:  Radiology       Date:  1975-08       Impact factor: 11.105

2.  Humeral-head and coracoid ossification in the newborn.

Authors:  L R Kuhns; M P Sherman; A K Poznanski; J F Holt
Journal:  Radiology       Date:  1973-04       Impact factor: 11.105

3.  Determination of neonatal maturation on the chest radiograph.

Authors:  L R Kuhns; M P Sherman; A K Poznanski
Journal:  Radiology       Date:  1972-03       Impact factor: 11.105

4.  Growth graphs for the clinical assessment of infants of varying gestational age.

Authors:  S G Babson; G I Benda
Journal:  J Pediatr       Date:  1976-11       Impact factor: 4.406

5.  Annual summary of vital statistics: 2010-2011.

Authors:  Brady E Hamilton; Donna L Hoyert; Joyce A Martin; Donna M Strobino; Bernard Guyer
Journal:  Pediatrics       Date:  2013-02-11       Impact factor: 7.124

6.  A new growth chart for preterm babies: Babson and Benda's chart updated with recent data and a new format.

Authors:  Tanis R Fenton
Journal:  BMC Pediatr       Date:  2003-12-16       Impact factor: 2.125

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.