Literature DB >> 25819358

Prospective, 1-year observational study of double-threaded tapered body dental implants with immediate loading.

Tae Hyung Kim1, Alena Knezevic2, Michael Jorgensen3, Sandra Rich4, Hessam Nowzari5.   

Abstract

STATEMENT OF PROBLEM: Unlike conventional loading protocols, the immediate loading of single implants has not been fully investigated.
PURPOSE: The purpose of this study was to assess the prosthetic and esthetic periimplant mucosal outcomes of immediately restored dental implants during a 1-year follow-up.
MATERIAL AND METHODS: Twenty participants meeting the established inclusion criteria received double-threaded, tapered body dental implants (SuperLine; Dentium). Implants were placed and stabilized at a minimum of 35 Ncm of torque and restored immediately after the surgery with interim restorations. These were replaced with definitive restorations 6 months after implant placement. Clinical measurements at each visit included resonance frequency analysis, the evaluation of the participants' oral health (gingival and plaque indices), and the esthetic outcome of the interim or definitive restoration.
RESULTS: Implants placed in this clinical study had a 100% success rate. The oral health and esthetic outcomes were favorable for all participants.
CONCLUSIONS: Double-threaded, tapered body dental implants that were placed and immediately restored with fixed interim prostheses and with definitive prostheses after 6 months remained stable and functional after 1 year.
Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2015        PMID: 25819358     DOI: 10.1016/j.prosdent.2014.12.016

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  3 in total

1.  Dental implant restoration for dentition defects improves clinical efficacy, masticatory function and patient comfort.

Authors:  Shichun Zhong; Mengzheng Chen; Renhui Gao; Chengjun Shu
Journal:  Am J Transl Res       Date:  2022-09-15       Impact factor: 3.940

Review 2.  Zirconium dioxide implants as an alternative to titanium: A systematic review.

Authors:  Ivana Comisso; Santiago Arias-Herrera; Saurabh Gupta
Journal:  J Clin Exp Dent       Date:  2021-05-01

Review 3.  Immediate Implants: Clinical Guidelines for Esthetic Outcomes.

Authors:  Mohammad A Javaid; Zohaib Khurshid; Muhammad S Zafar; Shariq Najeeb
Journal:  Dent J (Basel)       Date:  2016-06-13
  3 in total