Literature DB >> 25818760

Comparative evaluation of two matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) systems, Vitek MS and Microflex LT, for the identification of Gram-positive cocci routinely isolated in clinical microbiology laboratories.

Miae Lee1, Hae-Sun Chung2, Hee-Won Moon3, Sun Hwa Lee4, Kyungwon Lee5.   

Abstract

We evaluated the performance of two MALDI-TOF MS systems for the identification of clinically important Gram-positive cocci. Vitek MS and Microflex LT correctly identified 97.2% and 94.7%, respectively. Both systems offer reliable and rapid identification of clinically important Gram-positive cocci isolated in clinical laboratories, including staphylococci, streptococci, and enterococci. Expanding the databases, especially of coagulase-negative staphylococci and viridans streptococci, would enhance performance.
Copyright © 2015 Elsevier B.V. All rights reserved.

Keywords:  Bacterial species identification; Gram-positive cocci; Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS); Microflex LT; Vitek MS

Mesh:

Year:  2015        PMID: 25818760     DOI: 10.1016/j.mimet.2015.03.020

Source DB:  PubMed          Journal:  J Microbiol Methods        ISSN: 0167-7012            Impact factor:   2.363


  4 in total

1.  Whole genome sequencing as a tool for phylogenetic analysis of clinical strains of Mitis group streptococci.

Authors:  L H Rasmussen; R Dargis; K Højholt; J J Christensen; O Skovgaard; U S Justesen; F S Rosenvinge; C Moser; O Lukjancenko; S Rasmussen; X C Nielsen
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2016-06-20       Impact factor: 3.267

Review 2.  Performance of the matrix-assisted laser desorption ionization time-of-flight mass spectrometry system for rapid identification of streptococci: a review.

Authors:  W-T Fan; T-T Qin; R-R Bi; H-Q Kang; P Ma; B Gu
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2017-01-23       Impact factor: 3.267

3.  Application of Routine Diagnostic Procedure, VITEK 2 Compact, MALDI-TOF MS, and PCR Assays in Identification Procedure of Bacterial Strain with Ambiguous Phenotype.

Authors:  Marta Książczyk; Maciej Kuczkowski; Bartłomiej Dudek; Kamila Korzekwa; Anna Tobiasz; Agnieszka Korzeniowska-Kowal; Emil Paluch; Alina Wieliczko; Gabriela Bugla-Płoskońska
Journal:  Curr Microbiol       Date:  2016-01-25       Impact factor: 2.188

4.  Matrix-assisted Laser Desorption Ionization-Time-of-Flight Mass Spectrometry (MALDI-TOF MS) as a Reliable Tool to Identify Species of Catalase-negative Gram-positive Cocci not Belonging to the Streptococcus Genus.

Authors:  Marisa Almuzara; Claudia Barberis; Viviana Rojas Velázquez; Maria Soledad Ramirez; Angela Famiglietti; Carlos Vay
Journal:  Open Microbiol J       Date:  2016-12-28
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.