| Literature DB >> 25818225 |
I Elsohaby1, J T McClure, G P Keefe.
Abstract
BACKGROUND: Failure of transfer of passive immunity (FTPI) is the underlying predisposing risk factor for most early losses in dairy calves. Refractometers, either optical or digital, can be used to assess FTPI as a part of calf health monitoring program on dairy operations.Entities:
Keywords: Immunoglobulin G; Radial immunodiffusion assay; Serum total protein
Mesh:
Year: 2015 PMID: 25818225 PMCID: PMC4895506 DOI: 10.1111/jvim.12560
Source DB: PubMed Journal: J Vet Intern Med ISSN: 0891-6640 Impact factor: 3.333
Figure 1Frequency distributions of (A) serum immunoglobulin G (IgG) concentration measured by radial immunodiffusion (RID) assay, (B) percentage Brix (%Brix) determined by digital Brix refractometer, and (C) serum total protein determined by optical refractometer for 200 Holstein dairy calves.
Figure 2Scatter plots comparing (A) serum immunoglobulin G (IgG) concentration obtained by radial immunodiffusion (RID) assay with percentage Brix (%Brix), determined by digital refractometer (r = 0.79); (B) serum IgG concentration obtained by RID assay with serum total protein (STP), determined by optical refractometer (r = 0.74); (C) %Brix, determined by digital refractometer with STP obtained by optical refractometer (r = 0.73) for 200 Holstein dairy calves.
Diagnostic test characteristics for the digital Brix and optical refractometers for assessing failure of transfer of passive immunity using previously recommended cut‐off values compared with immunoglobulin G (<1,000 mg/dL) determined by radial immunodiffusion assay
| Refractometer | Test Characteristics | |||||
|---|---|---|---|---|---|---|
| Cut‐Off Value | Sensitivity (%) | Specificity (%) | PPV (%) | NPV (%) | Accuracy (%) | |
| Digital Brix values (%Brix) | 7.8 | 32.7 | 94.5 | 69.2 | 78.7 | 77.5 |
| 8.0 | 47.3 | 93.1 | 72.2 | 82.3 | 80.5 | |
| 8.2 | 76.4 | 85.5 | 66.7 | 90.5 | 83 | |
| 8.4 | 89.1 | 76.6 | 59 | 94.9 | 80 | |
| Optical values (g/dL) | 5 | 25.5 | 98.6 | 87.5 | 77.7 | 78.5 |
| 5.2 | 69.1 | 89 | 70.4 | 88.4 | 83.5 | |
| 5.5 | 80 | 80.7 | 61.1 | 91.4 | 80.5 | |
| 5.7 | 87.3 | 69 | 51.6 | 93.5 | 74 | |
PPV, Positive predictive value; NPV, Negative predictive value.
Figure 3Receiver operating characteristic (ROC) curve, the best combination of sensitivity and specificity for digital and optical refractometers obtained at a cut‐off value 8.3%Brix and 5.5 g/dL, respectively.
Level of agreement between results of refractometers and radial immunodiffusion assay for assessing of failure of transfer of passive immunity in 200 dairy calves
| Refractometers | Cut‐Off Value | Agreement | Kappa |
|
|---|---|---|---|---|
| Digital Brix | 8.3%Brix | 0.83 | 0.59 | .0001 |
| Optical | 5.5 g/dL | 0.81 | 0.55 | .0001 |
| Digital versus Optical | — | 0.85 | 0.65 | .0001 |