Ventricular conduction defects after transcatheter aortic valve implantation: a single-institute analysis.

Akira T Kawaguchi1, Cosimo D'Allessandro1, Jean Philippe Collet2, Philippe Cluzel3, Ralouka Makri4, Pascal Leprince1.   

Abstract

Patients with aortic stenosis tend to develop ventricular conduction problems, which are known adverse events following transcatheter aortic valve implantation (TAVI). Changes in ventricular conduction status after TAVI were analyzed in 195 consecutive patients from a single institute registered in FRANCE2 between February 2010 and June 2012. Among the 195 patients, 29 had a prior pacemaker implantation (+PM) and 6 had acute catastrophic hemodynamics that made a full electrocardiogram (ECG) unavailable. Among the remaining 160, PM was newly required in 28 (17.5%, PM+) but not in 132 (PM-), which included 21 (13.1%) who developed new left bundle branch block (BBB), 12 (7.5%) had right BBB, and 99 (61.9%) had no change. While PM requirement had no correlation with preoperative factors, there was significant association with the development of right BBB with Edwards Sapien/XT (P = 0.003), and new left BBB (P = 0.012) and complete heart block requiring PM with CoreValve (22.6% vs. Edwards Sapien/XT, 7.4%, P = 0.016). Whereas postoperative survival regarding PM status (+PM, PM+, PM-), vascular access, valve size or type showed no difference, delayed heart block (n = 12, Day 2 or later) was associated with poor survival (P = 0.038) compared with the remaining PM+ patients with earlier onset (n = 16, Day 0 or 1). As a result, PM+ patients (n = 28) had significantly longer intensive care unit (ICU) stay and hospitalization than PM- or +PM patients. The results suggest that ventricular conduction problems requiring PM occurred more frequently after TAVI (17.5%) than with usual surgical replacement. Nonetheless, conduction problems failed to influence postoperative survival for up to 3 years on average with use of PM, but therefore did increase medical costs.
Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Entities:  

Keywords:  Permanent pacemaker implantation; Single-institute experience; Transcatheter aortic valve implantation; Ventricular conduction defect

Mesh:

Year:  2015        PMID: 25818075     DOI: 10.1111/aor.12393

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  2 in total

1.  Mid- to Long-Term Clinical and Echocardiographic Effects of Post-procedural Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis.

Authors:  Shun Xu; Enrui Zhang; Zhiyong Qian; Jinyu Sun; Fengwei Zou; Yao Wang; Xiaofeng Hou; Jiangang Zou
Journal:  Front Cardiovasc Med       Date:  2022-06-28

2.  Impact of postprocedural permanent pacemaker implantation on clinical outcomes after transcatheter aortic valve replacement: a systematic review and meta-analysis.

Authors:  Ziwei Xi; Tong Liu; Jing Liang; Yu-Jie Zhou; Wei Liu
Journal:  J Thorac Dis       Date:  2019-12       Impact factor: 2.895

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.