Median prior constrained TV algorithm for sparse view low-dose CT reconstruction.

Yi Liu1, Hong Shangguan1, Quan Zhang1, Hongqing Zhu2, Huazhong Shu3, Zhiguo Gui4.   

Abstract

It is known that lowering the X-ray tube current (mAs) or tube voltage (kVp) and simultaneously reducing the total number of X-ray views (sparse view) is an effective means to achieve low-dose in computed tomography (CT) scan. However, the associated image quality by the conventional filtered back-projection (FBP) usually degrades due to the excessive quantum noise. Although sparse-view CT reconstruction algorithm via total variation (TV), in the scanning protocol of reducing X-ray tube current, has been demonstrated to be able to result in significant radiation dose reduction while maintain image quality, noticeable patchy artifacts still exist in reconstructed images. In this study, to address the problem of patchy artifacts, we proposed a median prior constrained TV regularization to retain the image quality by introducing an auxiliary vector m in register with the object. Specifically, the approximate action of m is to draw, in each iteration, an object voxel toward its own local median, aiming to improve low-dose image quality with sparse-view projection measurements. Subsequently, an alternating optimization algorithm is adopted to optimize the associative objective function. We refer to the median prior constrained TV regularization as "TV_MP" for simplicity. Experimental results on digital phantoms and clinical phantom demonstrated that the proposed TV_MP with appropriate control parameters can not only ensure a higher signal to noise ratio (SNR) of the reconstructed image, but also its resolution compared with the original TV method.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Keywords:  Low-dose CT; Median prior; Reconstruction; Sparse-view; Total variation

Mesh:

Year:  2015        PMID: 25817533     DOI: 10.1016/j.compbiomed.2015.03.003

Source DB:  PubMed          Journal:  Comput Biol Med        ISSN: 0010-4825            Impact factor:   4.589


  3 in total

1.  Augmentation of CBCT Reconstructed From Under-Sampled Projections Using Deep Learning.

Authors:  Zhuoran Jiang; Yingxuan Chen; Yawei Zhang; Yun Ge; Fang-Fang Yin; Lei Ren
Journal:  IEEE Trans Med Imaging       Date:  2019-04-23       Impact factor: 10.048

2.  Iterative reconstruction for photon-counting CT using prior image constrained total generalized variation.

Authors:  Shanzhou Niu; You Zhang; Yuncheng Zhong; Guoliang Liu; Shaohui Lu; Xile Zhang; Shengzhou Hu; Tinghua Wang; Gaohang Yu; Jing Wang
Journal:  Comput Biol Med       Date:  2018-10-22       Impact factor: 4.589

3.  A cycle generative adversarial network for improving the quality of four-dimensional cone-beam computed tomography images.

Authors:  Keisuke Usui; Koichi Ogawa; Masami Goto; Yasuaki Sakano; Shinsuke Kyougoku; Hiroyuki Daida
Journal:  Radiat Oncol       Date:  2022-04-07       Impact factor: 3.481

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.