| Literature DB >> 25815933 |
Hongchang Wang1, Yogesh Kashyap1, Kawal Sawhney1.
Abstract
X-ray dark-field imaging can provide inaccessible and complementary information compared to conventional absorption contrast imaging. However, extraction of the dark-field signal is difficult, and sophisticated optics are often required. In this Letter, we report a novel approach to generate high-quality dark-field images using a simple membrane. The dark-field image is extracted from the maximum correlation coefficient by applying a cross-correlation algorithm to a stack of speckle images collected by scanning a membrane in a transverse direction to the incident x-ray beam. The new method can also provide directional dark-field information, which is extremely useful for the study of strongly ordered systems. The potential of the proposed technique for nondestructive x-ray imaging is demonstrated by imaging representative samples.Mesh:
Substances:
Year: 2015 PMID: 25815933 DOI: 10.1103/PhysRevLett.114.103901
Source DB: PubMed Journal: Phys Rev Lett ISSN: 0031-9007 Impact factor: 9.161