Literature DB >> 25813969

An approach to using heart rate monitoring to estimate the ventilation and load of air pollution exposure.

Izabela Campos Cozza1, Dirce Maria Trevisan Zanetta2, Frederico Leon Arrabal Fernandes3, Francisco Marcelo Monteiro da Rocha4, Paulo Afonso de Andre5, Maria Lúcia Bueno Garcia6, Renato Batista Paceli3, Gustavo Faibischew Prado3, Mario Terra-Filho3, Paulo Hilário do Nascimento Saldiva7, Ubiratan de Paula Santos3.   

Abstract

BACKGROUND: The effects of air pollution on health are associated with the amount of pollutants inhaled which depends on the environmental concentration and the inhaled air volume. It has not been clear whether statistical models of the relationship between heart rate and ventilation obtained using laboratory cardiopulmonary exercise test (CPET) can be applied to an external group to estimate ventilation.
OBJECTIVES: To develop and evaluate a model to estimate respiratory ventilation based on heart rate for inhaled load of pollutant assessment in field studies.
METHODS: Sixty non-smoking men; 43 public street workers (public street group) and 17 employees of the Forest Institute (park group) performed a maximum cardiopulmonary exercise test (CPET). Regression equation models were constructed with the heart rate and natural logarithmic of minute ventilation data obtained on CPET. Ten individuals were chosen randomly (public street group) and were used for external validation of the models (test group). All subjects also underwent heart rate register, and particulate matter (PM2.5) monitoring for a 24-hour period.
RESULTS: For the public street group, the median difference between estimated and observed data was 0.5 (CI 95% -0.2 to 1.4) l/min and for the park group was 0.2 (CI 95% -0.2 to 1.2) l/min. In the test group, estimated values were smaller than the ones observed in the CPET, with a median difference of -2.4 (CI 95% -4.2 to -1.8) l/min. The mixed model estimated values suggest that this model is suitable for situations in which heart rate is around 120-140bpm.
CONCLUSION: The mixed effect model is suitable for ventilation estimate, with good accuracy when applied to homogeneous groups, suggesting that, in this case, the model could be used in field studies to estimate ventilation. A small but significant difference in the median of external validation estimates was observed, suggesting that the applicability of the model to external groups needs further evaluation.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Air pollution; Heart rate; Inhaled load estimate; Personal exposure; Ventilation

Mesh:

Substances:

Year:  2015        PMID: 25813969     DOI: 10.1016/j.scitotenv.2015.03.049

Source DB:  PubMed          Journal:  Sci Total Environ        ISSN: 0048-9697            Impact factor:   7.963


  3 in total

1.  Laboratory Validation of Hexoskin Biometric Shirt at Rest, Submaximal Exercise, and Maximal Exercise While Riding a Stationary Bicycle.

Authors:  Cara M Smith; Steven N Chillrud; Darby W Jack; Patrick Kinney; Qiang Yang; Aimee M Layton
Journal:  J Occup Environ Med       Date:  2019-04       Impact factor: 2.162

2.  Commuter exposure to particulate matter in urban public transportation of Xi'an, China.

Authors:  Zhaowen Qiu; Huihui Cao
Journal:  J Environ Health Sci Eng       Date:  2020-05-18

3.  A Novel Method for Quantifying the Inhaled Dose of Air Pollutants Based on Heart Rate, Breathing Rate and Forced Vital Capacity.

Authors:  Roby Greenwald; Matthew J Hayat; Jerusha Barton; Anastasia Lopukhin
Journal:  PLoS One       Date:  2016-01-25       Impact factor: 3.240

  3 in total