Literature DB >> 25812938

Using photoplethysmography in heart rate monitoring of patients with epilepsy.

Judith van Andel1, Constantin Ungureanu2, Ronald Aarts3, Frans Leijten4, Johan Arends5.   

Abstract

Heart rate is a useful neurophysiological sign when monitoring seizures in patients with epilepsy. In an ambulatory setting, heart rate is measured with ECG involving electrodes on the skin. This method is uncomfortable which is burdensome for patients and is sensitive to motion artifacts, which decrease the usability of measurements. In this study, green light photoplethysmography, an optical technique arising from the fitness industry, was evaluated for usefulness in a medical setting. Simultaneous overnight measurements of HR with a commercially available optical heart rate (OHR) sensor and with ECG (HRECG) were performed in 7 patients with epilepsy. Overall, there was no significant difference between OHR and HRECG in random 10-minute periods during wakefulness (p=0.69) and sleep (p=1.00). The Bland-Altman analysis showed negligible mean differences. Limits of agreement were higher during wakefulness and during the occurrence of two seizures possibly because of less reliable HRECG measurements due to motion artifacts. Optical heart rate seems less sensitive to these motion artifacts, and measurements are more user-friendly. The optical heart rate sensor may fill the gap of systems for ambulatory heart rate monitoring and can be especially useful in the context of seizure detection in patients with epilepsy.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Ambulatory monitoring; ECG; Epilepsy; Heart rate; Photoplethysmography; Seizure detection

Mesh:

Year:  2015        PMID: 25812938     DOI: 10.1016/j.yebeh.2015.02.018

Source DB:  PubMed          Journal:  Epilepsy Behav        ISSN: 1525-5050            Impact factor:   2.937


  8 in total

Review 1.  Seizure detection: do current devices work? And when can they be useful?

Authors:  Xiuhe Zhao; Samden D Lhatoo
Journal:  Curr Neurol Neurosci Rep       Date:  2018-05-23       Impact factor: 5.081

2.  Novel Seizure Biomarkers in Continuous Electrocardiograms from Pediatric Epilepsy Patients.

Authors:  Fiona Cheung; Phillip L Pearl; Catherine Stamoulis
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2021-11

Review 3.  Wearable Health Devices in Health Care: Narrative Systematic Review.

Authors:  Lin Lu; Jiayao Zhang; Yi Xie; Fei Gao; Song Xu; Xinghuo Wu; Zhewei Ye
Journal:  JMIR Mhealth Uhealth       Date:  2020-11-09       Impact factor: 4.773

Review 4.  Future opportunities for research in rescue treatments.

Authors:  James W Wheless; Daniel Friedman; Gregory L Krauss; Vikram R Rao; Michael R Sperling; Enrique Carrazana; Adrian L Rabinowicz
Journal:  Epilepsia       Date:  2022-09       Impact factor: 6.740

Review 5.  Seizure Diaries and Forecasting With Wearables: Epilepsy Monitoring Outside the Clinic.

Authors:  Benjamin H Brinkmann; Philippa J Karoly; Ewan S Nurse; Sonya B Dumanis; Mona Nasseri; Pedro F Viana; Andreas Schulze-Bonhage; Dean R Freestone; Greg Worrell; Mark P Richardson; Mark J Cook
Journal:  Front Neurol       Date:  2021-07-13       Impact factor: 4.003

6.  Long-term accelerometry-triggered video monitoring and detection of tonic-clonic and clonic seizures in a home environment: Pilot study.

Authors:  Anouk Van de Vel; Milica Milosevic; Bert Bonroy; Kris Cuppens; Lieven Lagae; Bart Vanrumste; Sabine Van Huffel; Berten Ceulemans
Journal:  Epilepsy Behav Case Rep       Date:  2016-04-06

7.  Automated Epileptic Seizure Detection Based on Wearable ECG and PPG in a Hospital Environment.

Authors:  Kaat Vandecasteele; Thomas De Cooman; Ying Gu; Evy Cleeren; Kasper Claes; Wim Van Paesschen; Sabine Van Huffel; Borbála Hunyadi
Journal:  Sensors (Basel)       Date:  2017-10-13       Impact factor: 3.576

8.  Atrial Fibrillation Detection Using a Novel Cardiac Ambulatory Monitor Based on Photo-Plethysmography at the Wrist.

Authors:  Alberto G Bonomi; Fons Schipper; Linda M Eerikäinen; Jenny Margarito; Ralph van Dinther; Guido Muesch; Helma M de Morree; Ronald M Aarts; Saeed Babaeizadeh; David D McManus; Lukas R C Dekker
Journal:  J Am Heart Assoc       Date:  2018-08-07       Impact factor: 5.501

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.