Literature DB >> 25800021

Ambient ionization and direct identification of volatile organic compounds with microwave-induced plasma mass spectrometry.

Dandan Li1, Yong-Hui Tian, Zhongjun Zhao, Wenwen Li, Yixiang Duan.   

Abstract

An innovative method of volatile organic compounds analysis by using microwave-induced plasma ionization (MIPI) source in combination with an ambient ion trap mass spectrometer is presented here. Using MIPI for direct sample vapor, analysis was achieved without any sample preparation or subsequent heating. The relative abundance of the target compounds can be obtained almost instantly within a few seconds. The ionization processes of different volatile compounds was optimized, and the limits of detection were identified in the range of 0.15-4.5 pptv or 0.73-8.80 pg ml(-1). The relative standard deviation (RSD) is in the range of 4-14%, while correlation coefficients of the working curves (R(2)) are better than 0.98. The new method possesses advantages of ease operation, time-saving, high sensitivity and inexpensive setup. In addition, the ionization processes of short n-alkane chains were investigated with the MIPI technique, and a unique [M + 13](+) was detected, which has not been reported in detail by any other related ionization techniques. An ionization mechanism was proposed on the basis of the experimental results obtained in this work and available information in literatures, in which the n-alkanes in the plasma environment possibly generate protonated cyclopentadiene [M - 5](+) or alkyl-substituted analogues as well as hydrous ions [M + 13](+) and [M + 13 + 18](+), as shown in Scheme 1 in the main text.
Copyright © 2015 John Wiley & Sons, Ltd.

Entities:  

Keywords:  ambient mass spectrometry; ionization mechanism; microwave-induced plasma; n-alkanes; volatile organic compound

Mesh:

Substances:

Year:  2015        PMID: 25800021     DOI: 10.1002/jms.3540

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  2 in total

1.  Investigation and Applications of In-Source Oxidation in Liquid Sampling-Atmospheric Pressure Afterglow Microplasma Ionization (LS-APAG) Source.

Authors:  Xiaobo Xie; Zhenpeng Wang; Yafeng Li; Lingpeng Zhan; Zongxiu Nie
Journal:  J Am Soc Mass Spectrom       Date:  2016-12-19       Impact factor: 3.109

2.  Glow Discharge Plasma Ionization Mass Spectrometry for Direct Detection of Oxygenated Organic Compounds in the Gas-phase.

Authors:  Yoko Nunome; Kenji Kodama; Kazuaki Wagatsuma
Journal:  Anal Sci       Date:  2019-10-11       Impact factor: 1.967

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.