Literature DB >> 25799705

Prediction of 30-day mortality after transcatheter aortic valve implantation: a comparison of logistic EuroSCORE, STS score, and EuroSCORE II.

Malin Johansson, Shahab Nozohoor, Igor Zindovic, Johan Nilsson, Per Ola Kimblad, Johan Sjögren.   

Abstract

BACKGROUND AND AIM OF THE STUDY: The logistic EuroSCORE and STS score have been used for the selection of suitable TAVI patients, but their predictive ability is unsatisfactory. The study aim was to evaluate the performance of the EuroSCORE II in predicting 30-day mortality after TAVI in comparison to the logistic EuroSCORE and STS scoring systems.
METHODS: Between January 2008 and April 2013, a total of 123 consecutive patients underwent TAVI (transapical, n = 85; transfemoral, n = 38) at the authors' institution. Calibration and discriminatory ability was evaluated for three risk scores models (logistic EuroSCORE, STS score, and EuroSCORE II), and compared for the prediction of 30-day mortality using the Hosmer-Lemeshow test for goodness-of-fit and receiver operating characteristics curve analysis.
RESULTS: The overall 30-day mortality was 4.1% (5/123). Predicted mortality was 25.0 ± 15.7% by logistic EuroSCORE, 7.3 ± 6.9% by STS score, and 7.8 ± 8.7% by EuroSCORE II. The observed/expected mortality ratio was 0.16 for logistic EuroSCORE, 0.56 for STS score, and 0.52 for EuroSCORE II. The area under the curve was 0.69 (95% CI 0.54-0.84) for the logistic EuroSCORE, 0.60 (95% CI 0.38-0.82) for the STS score, and 0.66 (95% CI 0.46-0.86) for the EuroSCORE II.
CONCLUSION: In the present study, the EuroSCORE II was found to predict 30-day mortality more accurately for the TAVI cohort than did the more established logistic EuroSCORE, and also to compare (at present) on a par with the STS score. However, there were no differences in discriminatory power between the models. It is believed that, in the absence of a more TAVI-oriented risk stratification system, the EuroSCORE II may be a valuable adjunct in the clinical setting.

Entities:  

Mesh:

Year:  2014        PMID: 25799705

Source DB:  PubMed          Journal:  J Heart Valve Dis        ISSN: 0966-8519


  3 in total

1.  Specific biomarkers of myocardial inflammation and remodeling processes as predictors of mortality in high-risk patients undergoing percutaneous mitral valve repair (MitraClip).

Authors:  Oliver Dörr; Claudia Walther; Christoph Liebetrau; Till Keller; Hannes Tabert; Niklas Boeder; Matthias Bayer; Pascal Bauer; Helge Möllmann; Luise Gaede; Christian Troidl; Sandra Voss; Timm Bauer; Christian W Hamm; Holger Nef
Journal:  Clin Cardiol       Date:  2018-04-17       Impact factor: 2.882

2.  Evaluation of cystatin C and neutrophil gelatinase-associated lipocalin as predictors of mortality in patients undergoing percutaneous mitral valve repair (MitraClip).

Authors:  Oliver Dörr; Claudia Walther; Christoph Liebetrau; Till Keller; Regine M Ortlieb; Niklas Boeder; Pascal Bauer; Helge Möllmann; Luise Gaede; Christian Troidl; Sandra Voss; Timm Bauer; Christian W Hamm; Holger Nef
Journal:  Clin Cardiol       Date:  2018-11-16       Impact factor: 2.882

3.  The association of diabetes mellitus treated with oral antidiabetic drugs and insulin with mortality after transcatheter valve implantation: a 3-year follow-up of the TAVIK registry.

Authors:  Panagiotis Tzamalis; Valentin Herzberger; Jens Bergmann; Alexander Wuerth; Peter Bramlage; Holger Schroefel; Claus Schmitt; Gerhard Schymik
Journal:  Cardiovasc Diabetol       Date:  2019-05-28       Impact factor: 9.951

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.