Literature DB >> 25797588

[Body plethysmography (I): Standardisation and quality criteria].

I de Mir Messa1, O Sardón Prado2, H Larramona3, A Salcedo Posadas4, J R Villa Asensi5.   

Abstract

Whole body plethysmography is used to measure lung volumes, capacities and resistances. It is a well standardised technique, and although it is widely used in paediatric chest diseases units, it requires specific equipment, specialist staff, and some cooperation by the patient. Plethysmography uses Boyle's law in order to measure the intrathoracic gas volume or functional residual capacity, and once this is determined, the residual volume and total lung capacity is extrapolated. The measurement of total lung capacity is necessary for the diagnosis of restrictive diseases. Airway resistance is a measurement of obstruction, with the total resistance being able to be measured, which includes chest wall, lung tissue and airway resistance, as well as the specific airway resistance, which is a more stable parameter that is determined by multiplying the measured values of airway resistance and functional residual capacity. The complexity of this technique, the reference equations, the differences in the equipment and their variability, and the conditions in which it is performed, has led to the need for its standardisation. Throughout this article, the practical aspects of plethysmography are analysed, specifying recommendations for performing it, its systematic calibration and the calculations that must be made, as well as the interpretation of the results obtained. The aim of this article is to provide a better understanding of the principles of whole body plethysmography with the aim of optimising the interpretation of the results, leading to improved management of the patient, as well as a consensus among the speciality.
Copyright © 2014 Asociación Española de Pediatría. Published by Elsevier España, S.L.U. All rights reserved.

Entities:  

Keywords:  Capacidad residual funcional; Functional residual capacity; Intrathoracic gas volume; Pletismografía corporal total; Resistencia específica de la vía aérea; Resistencia total de la vía aérea; Specific airway resistance; Total airway resistance; Volumen de gas intratorácico; Whole body plethysmography

Mesh:

Year:  2015        PMID: 25797588     DOI: 10.1016/j.anpedi.2014.10.029

Source DB:  PubMed          Journal:  An Pediatr (Barc)        ISSN: 1695-4033            Impact factor:   1.500


  2 in total

1.  Requirements for Supporting Diagnostic Equipment of Respiration Process in Humans.

Authors:  Szymon Nitkiewicz; Robert Barański; Marek Galewski; Hanna Zajączkiewicz; Andrzej Kukwa; Andrzej Zając; Stanisław Ejdys; Piotr Artiemjew
Journal:  Sensors (Basel)       Date:  2021-05-17       Impact factor: 3.576

2.  Body plethysmography in chronic obstructive pulmonary disease patients: A cross-sectional study.

Authors:  Yogesh Satyendra Gupta; Swati S Shah; Chaya K Ahire; Prathamesh Kamble; Anupam S Khare; S S More
Journal:  Lung India       Date:  2018 Mar-Apr
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.