A comparison of four DNA stains considered to be AT-specific with chromosomes from a clonal Chinese hamster cell line B14F28-C5 have been made. The flow karyotype histograms indicate that DAPI, DIPI, and Hoechst 33258 and 33342 do stain similarly in the same preparation. DAPI staining is specific and highly reproducible in this line. We, therefore, recommend this dye as a single chromosome DNA stain for high-resolution flow cytometric measurements in cytogenetics and mutation research.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 2579484     DOI: 10.3109/10520298509113885

Source DB:  PubMed          Journal:  Stain Technol        ISSN: 0038-9153


  7 in total

1.  Fluorescence intensity and anisotropy decays of the DNA stain Hoechst 33342 resulting from one-photon and two-photon excitation.

Authors:  I Gryczynski; J R Lakowicz
Journal:  J Fluoresc       Date:  1994-12       Impact factor: 2.217

2.  Flow cytometric analysis of marine bacteria with hoechst 33342.

Authors:  B C Monger; M R Landry
Journal:  Appl Environ Microbiol       Date:  1993-03       Impact factor: 4.792

3.  Rapid, fluorometric DNA determination for chick limb-bud mesenchymal-cell microcultures.

Authors:  D F Paulsen; W D Chen; T Scineaux; D Adams
Journal:  In Vitro Cell Dev Biol Anim       Date:  1998-02       Impact factor: 2.416

4.  The hazards of DAPI photoconversion: effects of dye, mounting media and fixative, and how to minimize the problem.

Authors:  Mojca Jež; Tuba Bas; Matija Veber; Andrej Košir; Tanja Dominko; Raymond Page; Primož Rožman
Journal:  Histochem Cell Biol       Date:  2012-10-14       Impact factor: 4.304

5.  Nucleolar Translocation of Histone Deacetylase 2 Is Involved in Regulation of Transcriptional Silencing in the Cat Germinal Vesicle.

Authors:  Pei-Chih Lee; David E Wildt; Pierre Comizzoli
Journal:  Biol Reprod       Date:  2015-06-24       Impact factor: 4.285

Review 6.  Flow Cytometry and Cell Cycle Analysis: An Overview.

Authors:  Aja M Rieger
Journal:  Methods Mol Biol       Date:  2022

7.  Rhodamine 6G conjugated to gold nanoparticles as labels for both SERS and fluorescence
studies on live endothelial cells.

Authors:  Aleksandra Jaworska; Tomasz Wojcik; Kamilla Malek; Urszula Kwolek; Mariusz Kepczynski; Abu A Ansary; Stefan Chlopicki; Malgorzata Baranska
Journal:  Mikrochim Acta       Date:  2014-06-19       Impact factor: 5.833