Literature DB >> 25792000

Validation of a Prescreening Program for Transcatheter Atrial Septal Defect Closure.

George T Nicholson1, Robert N Vincent, Christopher J Petit, Meredith Roman, Michelle Glanville, Dennis W Kim.   

Abstract

Prior to initiation of a formal screening program, 30 % of patients referred for device closure of an atrial septal defect (ASD) at our institution had atrial septal anatomy which precluded ASD device closure. This resulted in inefficiencies in workflow, staff utilization, and inconvenience for families. Our objective was to report our experience with an ASD prescreening evaluation/protocol and family consultation process. This is a retrospective study of pediatric patients who underwent a comprehensive ASD prescreening evaluation at Children's Healthcare of Atlanta between January 2011 and June 2013. The comprehensive prescreening process included a detailed transthoracic echocardiogram and family consultation. Upon establishing a formal prescreening process for patients with secundum ASDs, 138 patients were screened for appropriateness of ASD device closure. At time of prescreening, 40 patients (29 %) were deemed not to be suitable candidates for device ASD closure. In 9 patients (6.5 %), after discussion with the interventionalist, parents elected to pursue surgical ASD closure. A total of 78 patients (56.5 %) underwent successful transcutaneous ASD device closure. In addition, there was a significant discrepancy in the reported size of the ASD between the outside evaluation and the ASD size discovered during the prescreening process. The addition of a prescreening program for transcatheter ASD closure has decreased the incidence of unsuccessful ASD closure from 30 to 10.3 %. The use of a comprehensive evaluation process for ASD device closure improves the likelihood of successful device implantation and permits adequate preprocedural counseling for the patient and family.

Entities:  

Mesh:

Year:  2015        PMID: 25792000     DOI: 10.1007/s00246-015-1135-3

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  13 in total

Review 1.  Erosions, erosions, and erosions! Device closure of atrial septal defects: how safe is safe?

Authors:  Karim Diab; Damien Kenny; Ziyad M Hijazi
Journal:  Catheter Cardiovasc Interv       Date:  2012-08-01       Impact factor: 2.692

Review 2.  Echocardiography-guided interventions.

Authors:  Frank E Silvestry; Richard E Kerber; Michael M Brook; John D Carroll; Karen M Eberman; Steven A Goldstein; Howard C Herrmann; Shunichi Homma; Roxana Mehran; Douglas L Packer; Alfred F Parisi; Todd Pulerwitz; James Bernard Seward; Teresa S M Tsang; Mark A Wood
Journal:  J Am Soc Echocardiogr       Date:  2009-03       Impact factor: 5.251

3.  Recent changes in instructions for use for the Amplatzer atrial septal defect occluder: how to incorporate these changes while using transesophageal echocardiography or intracardiac echocardiography?

Authors:  Kiran Mallula; Zahid Amin
Journal:  Pediatr Cardiol       Date:  2012-05-11       Impact factor: 1.655

Review 4.  Percutaneous atrial septal occluder devices and cardiac erosion: a review of the literature.

Authors:  Geoffrey B Crawford; Ralph G Brindis; Mitchell W Krucoff; Benjamin P Mansalis; John D Carroll
Journal:  Catheter Cardiovasc Interv       Date:  2012-05-02       Impact factor: 2.692

5.  Late erosion of an Amplatzer septal occluder device 6 years after placement.

Authors:  Nathaniel W Taggart; Joseph A Dearani; Donald J Hagler
Journal:  J Thorac Cardiovasc Surg       Date:  2011-04-03       Impact factor: 5.209

Review 6.  Percutaneous versus surgical closure of secundum atrial septal defects: a systematic review and meta-analysis of currently available clinical evidence.

Authors:  Gianfranco Butera; Giuseppe Biondi-Zoccai; Giuseppe Sangiorgi; Raul Abella; Alessandro Giamberti; Claudio Bussadori; Imad Sheiban; Zackhia Saliba; Tiberio Santoro; Gabriele Pelissero; Mario Carminati; Alessandro Frigiola
Journal:  EuroIntervention       Date:  2011-07       Impact factor: 6.534

Review 7.  Transcatheter device closure of atrial septal defects: a safety review.

Authors:  John Moore; Sanjeet Hegde; Howaida El-Said; Robert Beekman; Lee Benson; Lisa Bergersen; Ralf Holzer; Kathy Jenkins; Richard Ringel; Jonathan Rome; Robert Vincent; Gerard Martin
Journal:  JACC Cardiovasc Interv       Date:  2013-05       Impact factor: 11.195

Review 8.  Percutaneous treatment of patent foramen ovale and atrial septal defects.

Authors:  Jonathan Tobis; Michael Shenoda
Journal:  J Am Coll Cardiol       Date:  2012-10-03       Impact factor: 24.094

9.  Erosion by the Amplatzer septal occluder: experienced operator opinions at odds with manufacturer recommendations?

Authors:  Howaida G El-Said; John W Moore
Journal:  Catheter Cardiovasc Interv       Date:  2009-06-01       Impact factor: 2.692

10.  Prevalence of congenital heart defects in metropolitan Atlanta, 1998-2005.

Authors:  Mark D Reller; Matthew J Strickland; Tiffany Riehle-Colarusso; William T Mahle; Adolfo Correa
Journal:  J Pediatr       Date:  2008-07-26       Impact factor: 4.406

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.