Literature DB >> 25791464

Electrochemiluminescence modified electrodes based on RuSi@Ru(bpy)3(2+) loaded with gold functioned nanoporous CO/Co3O4 for detection of mycotoxin deoxynivalenol.

Xiaohui Lv1, Yueyun Li2, Tao Yan1, Xuehui Pang1, Wei Cao1, Bin Du3, Dan Wu4, Qin Wei1.   

Abstract

Nanoporous cobalt (NPCo) with three-dimensional network nanostructure was obtained by selectively dealloying Al from CoAl alloy in a mild alkaline solution. Co3O4 grew further on the surface of NPCo and then NPCo/Co3O4 was obtained. Gold nanoparticles functionalized NPCo/Co3O4 (NPCo/Co3O4-Au) was used to fabricate electrochemiluminescence (ECL) modified electrodes for detecting mycotoxin deoxynivalenol (DON). In addition the introduction of AuNPs enhanced the conductivity, and NPCo/Co3O4-Au exhibited excellent catalytic properties for the luminescence of RuSi@Ru(bpy)3(2+). The fabricated ECL modified electrodes exhibited a high activity for DON in a wide linear range from 5 pg/mL to 100 ng/mL with a low detection limit of 1 pg/mL. The NPCo/Co3O4-Au based ECL modified electrodes displayed excellent stability and reproducibility, and successfully achieved the detection of DON in wheat flour with desirable results as well. The NPCo/Co3O4-Au possesses great application potential for ECL modified electrodes with sample detection, unique catalytic activity, and high structure stability.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Electrochemiluminescence; Modified electrodes; Mycotoxin deoxynivalenol; Nanoporous cobalt; RuSi@Ru(bpy)(3)(2+)

Mesh:

Substances:

Year:  2015        PMID: 25791464     DOI: 10.1016/j.bios.2015.03.020

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  A novel self-enhanced electrochemiluminescence immunosensor based on hollow Ru-SiO2@PEI nanoparticles for NSE analysis.

Authors:  Limin Zhou; Jianshe Huang; Bin Yu; Tianyan You
Journal:  Sci Rep       Date:  2016-02-26       Impact factor: 4.379

Review 2.  Advances in Biosensors, Chemosensors and Assays for the Determination of Fusarium Mycotoxins.

Authors:  Xialu Lin; Xiong Guo
Journal:  Toxins (Basel)       Date:  2016-05-24       Impact factor: 4.546

Review 3.  Trends and Advances in Electrochemiluminescence Nanobiosensors.

Authors:  Mohammad Rizwan; Noor Faizah Mohd-Naim; Minhaz Uddin Ahmed
Journal:  Sensors (Basel)       Date:  2018-01-09       Impact factor: 3.576

Review 4.  Nanoparticles as a Solution for Eliminating the Risk of Mycotoxins.

Authors:  Pavel Horky; Sylvie Skalickova; Daria Baholet; Jiri Skladanka
Journal:  Nanomaterials (Basel)       Date:  2018-09-14       Impact factor: 5.076

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.