Tapered-slit membrane filters for high-throughput viable circulating tumor cell isolation.

Yoon-Tae Kang1, Il Doh, Young-Ho Cho.   

Abstract

This paper presents tapered-slit membrane filters for high-throughput viable circulating tumor cell (CTC) isolation. The membrane filter with a 2D array of vertical tapered slits with a gap that is wide at the entrance and gradually decreases with depth, provide minimal cell stress and reduce 82.14% of the stress generated in conventional straight-hole filters. We designed two types of tapered-slit filters, Filters 6 and 8, respectively, containing the tapered slits with outlet widths of 6 μm and 8 μm at a slit density of 34,445/cm(2) on the membrane. We fabricated the vertical slits with a tapered angle of 2 ° on a SU8 membrane by adjusting the UV expose dose and the air gap between the membrane and the photomask during lithography. In the experimental study, the proposed tapered-slit filter captured 89.87% and 82.44% of the cancer cells spiked in phosphate buffered saline (PBS) and diluted blood (blood: PBS = 1:4), respectively, at a sample flow rate of 5 ml per hour, which is 33.3 times faster than previous lateral tapered-slit filters. We further verified the capability to culture on chip after capturing: 72.33% of cells among the captured cells still remained viable after a 5-day culture. The proposed tapered-slit membrane filters verified high-throughput viable CTC isolation capability, thereby inaugurating further advanced CTC research for cancer diagnosis and prognosis.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25790944     DOI: 10.1007/s10544-015-9949-6

Source DB:  PubMed          Journal:  Biomed Microdevices        ISSN: 1387-2176            Impact factor:   2.838


  11 in total

1.  Detection of circulating tumour cells and their potential use as a biomarker for advanced renal cell carcinoma.

Authors:  Tae Heon Kim; Yoon-Tae Kang; Young-Ho Cho; Jeong Hoon Kim; Byong Chang Jeong; Seong Il Seo; Seong Soo Jeon; Hyun Moo Lee
Journal:  Can Urol Assoc J       Date:  2019-01-21       Impact factor: 1.862

Review 2.  Phenotype of circulating tumor cell: face-off between epithelial and mesenchymal masks.

Authors:  Yupeng Hong; Qi Zhang
Journal:  Tumour Biol       Date:  2016-01-13

3.  Circulating tumor cells are associated with poor outcomes in early-stage hepatocellular carcinoma: a prospective study.

Authors:  Yeonjung Ha; Tae Hun Kim; Jae Eul Shim; Sunghyun Yoon; Mi Jung Jun; Young-Ho Cho; Han Chu Lee
Journal:  Hepatol Int       Date:  2019-11-05       Impact factor: 6.047

4.  Cytopathological Study of the Circulating Tumor Cells filtered from the Cancer Patients' Blood using Hydrogel-based Cell Block Formation.

Authors:  Yoon-Tae Kang; Young Jun Kim; Tae Hee Lee; Young-Ho Cho; Hee Jin Chang; Hyun-Moo Lee
Journal:  Sci Rep       Date:  2018-10-12       Impact factor: 4.379

5.  Deterministic Capture of Individual Circulating Tumor Cells Using a Flow-Restricted Microfluidic Trap Array.

Authors:  Yousang Yoon; Jusin Lee; Ki-Chun Yoo; Onejae Sul; Su-Jae Lee; Seung-Beck Lee
Journal:  Micromachines (Basel)       Date:  2018-03-02       Impact factor: 2.891

6.  Post-debulking circulating tumor cell as a poor prognostic marker in advanced stage ovarian cancer: A prospective observational study.

Authors:  Miseon Kim; Dong Hoon Suh; Jin Young Choi; Jiyoon Bu; Yoon-Tae Kang; Kidong Kim; Jae Hong No; Yong Beom Kim; Young-Ho Cho
Journal:  Medicine (Baltimore)       Date:  2019-05       Impact factor: 1.817

7.  Label-free Rapid Viable Enrichment of Circulating Tumor Cell by Photosensitive Polymer-based Microfilter Device.

Authors:  Yoon-Tae Kang; Il Doh; Jiyoung Byun; Hee Jin Chang; Young-Ho Cho
Journal:  Theranostics       Date:  2017-07-22       Impact factor: 11.556

8.  Circulating tumor cells in the differential diagnosis of adnexal masses.

Authors:  Dong Hoon Suh; Miseon Kim; Jin Young Choi; Jiyoon Bu; Yoon-Tae Kang; Byung Su Kwon; Banghyun Lee; Kidong Kim; Jae Hong No; Yong-Beom Kim; Young-Ho Cho
Journal:  Oncotarget       Date:  2017-08-24

9.  Characterization of a novel automated microfiltration device for the efficient isolation and analysis of circulating tumor cells from clinical blood samples.

Authors:  Juan F Yee-de León; Brenda Soto-García; Diana Aráiz-Hernández; Jesús Rolando Delgado-Balderas; Miguel Esparza; Carlos Aguilar-Avelar; J D Wong-Campos; Franco Chacón; José Y López-Hernández; A Mauricio González-Treviño; José R Yee-de León; Jorge L Zamora-Mendoza; Mario M Alvarez; Grissel Trujillo-de Santiago; Lauro S Gómez-Guerra; Celia N Sánchez-Domínguez; Liza P Velarde-Calvillo; Alejandro Abarca-Blanco
Journal:  Sci Rep       Date:  2020-05-05       Impact factor: 4.379

10.  2.5-Dimensional Parylene C micropore array with a large area and a high porosity for high-throughput particle and cell separation.

Authors:  Yaoping Liu; Han Xu; Wangzhi Dai; Haichao Li; Wei Wang
Journal:  Microsyst Nanoeng       Date:  2018-06-18       Impact factor: 7.127