Literature DB >> 25790813

Assessment of modifications in thickness, curvatures, and volume upon the cornea caused by disposable soft contact lens wear.

Antonio J Del Águila-Carrasco1, Alberto Domínguez-Vicent, Cari Pérez-Vives, Teresa Ferrer-Blasco, Robert Montés-Micó.   

Abstract

PURPOSE: To assess the effect of different disposable soft contact lenses on several corneal parameters-thickness, anterior and posterior curvature, and volume-by means of a Scheimpflug imaging-based device (Pentacam HR). Diurnal variations of these parameters were taken into account.
METHODS: Twenty-one young, healthy subjects wore 4 different types of daily disposable soft contact lenses on 4 different days: Dailies AquaComfort Plus, SofLens, Dailies Total1, and Acuvue TruEye. The lenses had different material and water content. Pachymetry and curvature maps and corneal volume values were obtained using the Pentacam HR twice a day: one before putting the lens on and one after an 8-hour period of contact lens wear. Measurements were also taken without any contact lenses being worn.
RESULTS: Regarding corneal thickness, the lens with the most similar behavior to the naked eye scenario was the Dailies Total1, causing a thickening of 0.2 ± 0.1% in the central zone and 0.6 ± 0.2% in the periphery. All 4 lenses caused a slight but not significant flattening in the anterior corneal curvature, whereas the posterior corneal curvature only experienced a significant but small steepening with the SofLens. The use of these lenses increased corneal volume slightly.
CONCLUSIONS: Variations in corneal parameters seem to depend on the type of contact lens used (material, oxygen transmissibility, water content). However, the magnitude of the changes introduced by the use of soft contact lenses over the 8-hour period was small and probably not large enough to influence either visual acuity or comfort.

Entities:  

Mesh:

Year:  2015        PMID: 25790813     DOI: 10.5301/ejo.5000592

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  2 in total

1.  Revisiting the Robustness of Pentacam HR Indices Against Soft Contact Lens Wear.

Authors:  Rania Serag Elkitkat; Tamer Abdelfattah Badran; Weam Mohamed Ebeid
Journal:  Clin Ophthalmol       Date:  2021-04-15

2.  Double Eyelid Tape Wear Affects Anterior Ocular Health among Young Adult Women with Single Eyelids.

Authors:  Pui Theng Yong; Norlaili Arif; Sharanjeet Sharanjeet-Kaur; Mohd Izzuddin Hairol
Journal:  Int J Environ Res Public Health       Date:  2020-10-22       Impact factor: 3.390

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.