Literature DB >> 25790220

Equivalence between invasive and oscillometric blood pressures at different anatomic locations in healthy normotensive anaesthetised horses.

C C Tearney1, A G P Guedes2, R J Brosnan2.   

Abstract

REASONS FOR PERFORMING STUDY: Accurate blood pressure measurement is essential for effective clinical assessment and appropriate interventions in anaesthetised horses. Information on the accuracy of oscillometry for blood pressure measurement on the appendages of mature horses is limited.
OBJECTIVES: To assess equivalence between invasive and oscillometric blood pressures at different anatomic locations in horses. STUDY
DESIGN: Prospective experimental study using 6 healthy mature horses.
METHODS: Blood pressure was measured invasively in the right transverse facial artery and noninvasively by oscillometry in nondependent limbs and tail of laterally recumbent sevoflurane- or desflurane-anaesthetised horses. Cuff widths of 5-12 cm were tested on the tail, metatarsus, metacarpus and distal radius/ulna. Equivalence between mean arterial pressure (MAP) oscillometric and MAP invasive was assessed using a linear mixed effects model with a significance level of P≤0.05.
RESULTS: Twenty paired measurements were obtained for each cuff size in each of the locations, totalling 340 measurements. There was only one location (tail) and one cuff width (6 cm; cuff width-to-tail circumference ratio of 0.25) that resulted in equivalence between MAP measured with the oscillometric and the invasive methods (P = 0.8). All other locations (metacarpus, radius/ulna, metatarsus) and cuff widths were not equivalent (P≤0.01).
CONCLUSIONS: A cuff width-to-tail circumference ratio of 0.25 is recommended for accurate oscillometric blood pressure measurement in mature, laterally recumbent anaesthetised normotensive horses. Studies with variable haemodynamics are warranted. Oscillometric measurements at other extremities and/or with other cuff sizes cannot be recommended for clinical use.
© 2015 EVJ Ltd.

Entities:  

Keywords:  blood pressure cuff; cardiovascular monitoring; horse; indirect blood pressure; noninvasive blood pressure

Mesh:

Year:  2015        PMID: 25790220     DOI: 10.1111/evj.12443

Source DB:  PubMed          Journal:  Equine Vet J        ISSN: 0425-1644            Impact factor:   2.888


  3 in total

1.  Accuracy and Precision of Noninvasive Blood Pressure in Normo-, Hyper-, and Hypotensive Standing and Anesthetized Adult Horses.

Authors:  N Heliczer; O Lorello; D Casoni; C Navas de Solis
Journal:  J Vet Intern Med       Date:  2016-04-05       Impact factor: 3.333

2.  Diagnostic value of noninvasive pulse pressure measurements in Warmblood horses with aortic regurgitation.

Authors:  Julia Boegli; Colin C Schwarzwald; Katharyn J Mitchell
Journal:  J Vet Intern Med       Date:  2019-04-02       Impact factor: 3.333

3.  Agreement of High-Definition Oscillometry (HDO) and Invasive Blood Pressure Measurements at a Metatarsal Artery in Isoflurane-Anaesthetised Horses.

Authors:  Lara Twele; Stephan Neudeck; Julien Delarocque; Nicole Verhaar; Julia Reiners; Mike Noll; Julia Tünsmeyer; Sabine B R Kästner
Journal:  Animals (Basel)       Date:  2022-02-02       Impact factor: 2.752

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.