| Literature DB >> 25789815 |
Stefania Camagni1, Alessandro Lucianetti1, Paolo Ravelli2, Giovanni B Di Dedda3, Ezio Bonanomi3, Vittorio Corno1, Alessandro Aluffi1, Domenico Pinelli1, Marco F Zambelli1, Michela Guizzetti1, Piercarlo Parigi2, Michele Colledan1.
Abstract
We describe an unprecedented, disastrous complication after bilateral lung transplantation (BLT), a bilateral bronchial dehiscence with a right bronchoesophageal fistula leading to life-threatening septic shock. We also report the successful endoscopic management of this complication by double stenting and stress the efficacy of the multidisciplinary approach to this critical case.Entities:
Keywords: airway complication; bronchoesophageal fistula; lung transplantation; respiratory-digestive fistula
Mesh:
Year: 2015 PMID: 25789815 DOI: 10.1111/tri.12561