Proton pencil beam scanning for mediastinal lymphoma: the impact of interplay between target motion and beam scanning.

C Zeng1, J P Plastaras, Z A Tochner, B M White, C E Hill-Kayser, S M Hahn, S Both.   

Abstract

The purpose of this study was to assess the feasibility of proton pencil beam scanning (PBS) for the treatment of mediastinal lymphoma. A group of 7 patients of varying tumor size (100-800 cc) were planned using a PBS anterior field. We investigated 17 fractions of 1.8 Gy(RBE) to deliver 30.6 Gy(RBE) to the internal target volume (ITV). Spots with σ ranging from 4 mm to 8 mm were used for all patients, while larger spots (σ = 6-16 mm) were employed for patients with motion perpendicular to the beam (⩾5 mm), based on initial 4-dimensional computed tomography (4D CT) motion evaluation. We considered volumetric repainting such that the same field would be delivered twice in each fraction. The ratio of extreme inhalation amplitude and regular tidal inhalation amplitude (free-breathing variability) was quantified as an indicator of potential irregular breathing during the scanning. Four-dimensional dose was calculated on the 4D CT scans based on the respiratory trace and beam delivery sequence, implemented by partitioning the spots into separate plans on each 4D CT phase. Four starting phases (end of inhalation, end of exhalation, middle of inhalation and middle of exhalation) were sampled for each painting and 4 energy switching times (0.5 s, 1 s, 3 s and 5 s) were tested, which resulted in 896 dose distributions for the analyzed cohort. Plan robustness was measured for the target and critical structures in terms of the percent difference between 'delivered' dose (4D-evaluated) and planned dose (calculated on average CT). It was found that none of the patients exhibited highly variable or chaotic breathing patterns. For all patients, the ITV D98% was degraded by <2% (standard deviations ∼ 0.1%) when averaged over the whole treatment course. For six out of seven patients, the average degradation of ITV D98% per fraction was within 5% . For one patient with motion perpendicular to the beam (⩾5 mm), the degradation of ITV D98% per fraction was up to 15%, which was mitigated to 2% by employing larger spots and repainting. Deviation of mean lung dose was at most 0.2 Gy(RBE) (less than 1% of prescribed dose, 30.6 Gy(RBE)), while the deviation of heart maximum dose and cord maximum dose could exceed 5% of the prescribed dose. No significant difference in either target coverage or normal tissue dose was observed for different energy switching times compared via two-sided Wilcoxon signed-rank tests (p < 0.05). This feasibility study demonstrates that, for mediastinal lymphoma, the impact of the interplay effect on the PBS plan robustness is minimal when volumetric repainting and/or larger spots are employed.

Entities:  

Mesh:

Year:  2015        PMID: 25789418     DOI: 10.1088/0031-9155/60/7/3013

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Proton therapy for adults with mediastinal lymphomas: the International Lymphoma Radiation Oncology Group guidelines.

Authors:  Bouthaina Shbib Dabaja; Bradford S Hoppe; John P Plastaras; Wayne Newhauser; Katerina Rosolova; Stella Flampouri; Radhe Mohan; N George Mikhaeel; Youlia Kirova; Lena Specht; Joachim Yahalom
Journal:  Blood       Date:  2018-08-14       Impact factor: 22.113

2.  Life years lost attributable to late effects after radiotherapy for early stage Hodgkin lymphoma: The impact of proton therapy and/or deep inspiration breath hold.

Authors:  Laura Ann Rechner; Maja Vestmø Maraldo; Ivan Richter Vogelius; Xiaorong Ronald Zhu; Bouthaina Shbib Dabaja; Nils Patrik Brodin; Peter Meidahl Petersen; Lena Specht; Marianne Camille Aznar
Journal:  Radiother Oncol       Date:  2017-08-30       Impact factor: 6.280

Review 3.  Proton beam radiotherapy for patients with early-stage and advanced lung cancer: a narrative review with contemporary clinical recommendations.

Authors:  Jennifer S Chiang; Nathan Y Yu; Thomas B Daniels; Wei Liu; Steven E Schild; Terence T Sio
Journal:  J Thorac Dis       Date:  2021-02       Impact factor: 2.895

4.  Interplay Effect of Target Motion and Pencil-Beam Scanning in Proton Therapy for Pediatric Patients.

Authors:  Andrew J Boria; Jinsoo Uh; Fakhriddin Pirlepesov; James C Stuckey; Marian Axente; Melissa A Gargone; Chia-Ho Hua
Journal:  Int J Part Ther       Date:  2018-11-30

5.  Technical Note: Multiple energy extraction techniques for synchrotron-based proton delivery systems may exacerbate motion interplay effects in lung cancer treatments.

Authors:  James E Younkin; Danairis Hernandez Morales; Jiajian Shen; Xiaoning Ding; Joshua B Stoker; Nathan Y Yu; Terence T Sio; Thomas B Daniels; Martin Bues; Mirek Fatyga; Steven E Schild; Wei Liu
Journal:  Med Phys       Date:  2021-07-29       Impact factor: 4.506

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.