Literature DB >> 25787123

Measurement of tumor blood flow in head and neck squamous cell carcinoma by pseudo-continuous arterial spin labeling: comparison with dynamic contrast-enhanced MRI.

Noriyuki Fujima1, Kohsuke Kudo, Akiko Tsukahara, Daisuke Yoshida, Tomohiro Sakashita, Akihiro Homma, Khin Khin Tha, Hiroki Shirato.   

Abstract

PURPOSE: To investigate the feasibility of tumor blood flow (TBF) measurement in head and neck squamous cell carcinoma (HNSCC) using pseudo-continuous arterial spin labeling (pCASL) in a comparison with dynamic contrast-enhanced (DCE) perfusion.
MATERIALS AND METHODS: We prospectively scanned 18 patients with HNSCC using 3T magnetic resonance imaging (MRI) with both pCASL and DCE perfusion. Quantitative TBF value in the whole-tumor region of interest (ROI), and regional TBF in the ROIs of the central and peripheral areas in the tumor were respectively measured. Relative TBF value in the whole-tumor ROI was also calculated. We determined the correlation and agreement between each measured TBF by pCASL and DCE perfusion using Pearson's correlation coefficients, intraclass correlation coefficients (ICC), and Bland-Altman analysis.
RESULTS: In the whole-tumor ROIs, significant correlation was observed between the absolute TBF values (r = 0.72, P < 0.01), with an ICC of 0.72; moreover, higher correlation was observed in the relative TBF (r = 0.79). The correlation was higher in the peripheral ROI (r = 0.70) than the central ROI (r = 0.65), with an ICC of 0.62 and 0.54, respectively. Bland-Altman plots revealed the underestimation of TBF by pCASL in central ROIs.
CONCLUSION: TBF measurement by pCASL was feasible in patients with HNSCC. J. Magn. Reson. Imaging 2015;41:1-1.
© 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  dynamic contrast-enhanced perfusion; head and neck squamous cell carcinoma; pseudo-continuous arterial spin labeling; tumor blood flow

Mesh:

Substances:

Year:  2015        PMID: 25787123     DOI: 10.1002/jmri.24885

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  4 in total

1.  Multi-parametric arterial spin labeling and diffusion-weighted imaging of paranasal sinuses masses.

Authors:  Doaa Khedr; Ahmed Abdel Khalek Abdel Razek; Mona Talaat
Journal:  Oral Radiol       Date:  2022-07-28       Impact factor: 1.882

2.  Histogram analysis of arterial spin labeling perfusion data to determine the human papillomavirus status of oropharyngeal squamous cell carcinomas.

Authors:  Yura Ahn; Young Jun Choi; Yu Sub Sung; Josef Pfeuffer; Chong Hyun Suh; Sae Rom Chung; Jung Hwan Baek; Jeong Hyun Lee
Journal:  Neuroradiology       Date:  2021-06-29       Impact factor: 2.804

3.  Differentiating malignant from benign salivary gland lesions: a multiparametric non-contrast MR imaging approach.

Authors:  Koji Takumi; Hiroaki Nagano; Hidehiko Kikuno; Yuichi Kumagae; Yoshihiko Fukukura; Takashi Yoshiura
Journal:  Sci Rep       Date:  2021-02-02       Impact factor: 4.379

Review 4.  Pseudocontinuous Arterial Spin Labeling: Clinical Applications and Usefulness in Head and Neck Entities.

Authors:  Fumine Tanaka; Maki Umino; Masayuki Maeda; Ryohei Nakayama; Katsuhiro Inoue; Ryota Kogue; Makoto Obara; Hajime Sakuma
Journal:  Cancers (Basel)       Date:  2022-08-11       Impact factor: 6.575

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.