Literature DB >> 25781624

Accuracy and Precision of Head Motion Information in Multi-Channel Free Induction Decay Navigators for Magnetic Resonance Imaging.

Maryna Babayeva, Tobias Kober, Benjamin Knowles, Michael Herbst, Reto Meuli, Maxim Zaitsev, Gunnar Krueger.   

Abstract

Free induction decay (FID) navigators were found to qualitatively detect rigid-body head movements, yet it is unknown to what extent they can provide quantitative motion estimates. Here, we acquired FID navigators at different sampling rates and simultaneously measured head movements using a highly accurate optical motion tracking system. This strategy allowed us to estimate the accuracy and precision of FID navigators for quantification of rigid-body head movements. Five subjects were scanned with a 32-channel head coil array on a clinical 3T MR scanner during several resting and guided head movement periods. For each subject we trained a linear regression model based on FID navigator and optical motion tracking signals. FID-based motion model accuracy and precision was evaluated using cross-validation. FID-based prediction of rigid-body head motion was found to be with a mean translational and rotational error of 0.14±0.21 mm and 0.08±0.13°, respectively. Robust model training with sub-millimeter and sub-degree accuracy could be achieved using 100 data points with motion magnitudes of ±2 mm and ±1° for translation and rotation. The obtained linear models appeared to be subject-specific as inter-subject application of a "universal" FID-based motion model resulted in poor prediction accuracy. The results show that substantial rigid-body motion information is encoded in FID navigator signal time courses. Although, the applied method currently requires the simultaneous acquisition of FID signals and optical tracking data, the findings suggest that multi-channel FID navigators have a potential to complement existing tracking technologies for accurate rigid-body motion detection and correction in MRI.

Mesh:

Year:  2015        PMID: 25781624     DOI: 10.1109/TMI.2015.2413211

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  4 in total

1.  Motion correction for diffusion weighted SMS imaging.

Authors:  M Herbst; B A Poser; A Singh; W Deng; B Knowles; M Zaitsev; V A Stenger; T Ernst
Journal:  Magn Reson Imaging       Date:  2016-12-15       Impact factor: 2.546

2.  Head motion measurement and correction using FID navigators.

Authors:  Tess E Wallace; Onur Afacan; Maryna Waszak; Tobias Kober; Simon K Warfield
Journal:  Magn Reson Med       Date:  2018-07-29       Impact factor: 4.668

3.  Scout accelerated motion estimation and reduction (SAMER).

Authors:  Daniel Polak; Daniel Nicolas Splitthoff; Bryan Clifford; Wei-Ching Lo; Susie Y Huang; John Conklin; Lawrence L Wald; Kawin Setsompop; Stephen Cauley
Journal:  Magn Reson Med       Date:  2021-08-13       Impact factor: 4.668

4.  Motion correction methods for MRS: experts' consensus recommendations.

Authors:  Ovidiu C Andronesi; Pallab K Bhattacharyya; Wolfgang Bogner; In-Young Choi; Aaron T Hess; Phil Lee; Ernesta M Meintjes; M Dylan Tisdall; Maxim Zaitzev; André van der Kouwe
Journal:  NMR Biomed       Date:  2020-07-20       Impact factor: 4.044

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.