Usefulness of sonication of cardiovascular implantable electronic devices to enhance microbial detection.

Avish Nagpal1, Robin Patel2, Kerryl E Greenwood-Quaintance3, Larry M Baddour4, David T Lynch3, Brian D Lahr5, Joseph J Maleszewski6, Paul A Friedman7, David L Hayes7, M Rizwan Sohail8.   

Abstract

The cardiovascular implantable electronic device (CIED) infection rate is rising disproportionately to the rate of device implantation. Identification of microorganisms that cause CIED infections is not always achieved using present laboratory techniques. We conducted a prospective study to determine whether device vortexing-sonication followed by culture of the resulting sonicate fluid would enhance microbial detection compared with traditional swab or pocket tissue cultures. Forty-two subjects with noninfected and 35 with infected CIEDs were prospectively enrolled over 12 months. One swab each from the device pocket and device surface, pocket tissue, and the CIED were collected from each patient. Swabs and tissues were cultured using routine methods. The CIED was processed in Ringer's solution using vortexing-sonication and the resultant fluid semiquantitatively cultured. Tissue and swab growth was considered significant when colonies grew on ≥2 quadrants of the culture plate and device was considered significant when ≥20 colonies were isolated from 10 ml of sonicate fluid. In noninfected group, 5% of sonicate fluids yielded significant bacterial growth, compared with 5% of tissue cultures (p = 1.00) and 2% of both pocket and device swab cultures (p = 0.317 each). In infected group, significant bacterial growth was observed in 54% of sonicate fluids, significantly greater than the sensitivities of pocket swab (20%, p = 0.001), device swab (9%, p <0.001), or tissue (9%, p <0.001) culture. In conclusion, vortexing-sonication of CIEDs with semiquantitative culture of the resultant sonicate fluid results in a significant increase in the sensitivity of culture results, compared with swab or tissue cultures.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2015        PMID: 25779615      PMCID: PMC4545652          DOI: 10.1016/j.amjcard.2015.01.017

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  25 in total

1.  Proposed modifications to the Duke criteria for the diagnosis of infective endocarditis.

Authors:  J S Li; D J Sexton; N Mick; R Nettles; V G Fowler; T Ryan; T Bashore; G R Corey
Journal:  Clin Infect Dis       Date:  2000-04-03       Impact factor: 9.079

2.  Implant sonication for the diagnosis of prosthetic elbow infection.

Authors:  Paschalis Vergidis; Kerryl E Greenwood-Quaintance; Joaquin Sanchez-Sotelo; Bernard F Morrey; Scott P Steinmann; Melissa J Karau; Douglas R Osmon; Jayawant N Mandrekar; James M Steckelberg; Robin Patel
Journal:  J Shoulder Elbow Surg       Date:  2011-12       Impact factor: 3.019

Review 3.  Treatment of infections associated with surgical implants.

Authors:  Rabih O Darouiche
Journal:  N Engl J Med       Date:  2004-04-01       Impact factor: 91.245

4.  Mortality and cost associated with cardiovascular implantable electronic device infections.

Authors:  Muhammad R Sohail; Charles A Henrikson; Mary Jo Braid-Forbes; Kevin F Forbes; Daniel J Lerner
Journal:  Arch Intern Med       Date:  2011-09-12

5.  Timing of the most recent device procedure influences the clinical outcome of lead-associated endocarditis results of the MEDIC (Multicenter Electrophysiologic Device Infection Cohort).

Authors:  Arnold J Greenspon; Jordan M Prutkin; Muhammad R Sohail; Holenarasipur R Vikram; Larry M Baddour; Stephan B Danik; James Peacock; Carlos Falces; Jose M Miro; Elisabeth Blank; Christoph Naber; Roger G Carrillo; Chi-Hong Tseng; Daniel Z Uslan
Journal:  J Am Coll Cardiol       Date:  2012-02-14       Impact factor: 24.094

6.  Pacemaker infective endocarditis.

Authors:  P Cacoub; P Leprince; P Nataf; P Hausfater; R Dorent; B Wechsler; V Bors; A Pavie; J C Piette; I Gandjbakhch
Journal:  Am J Cardiol       Date:  1998-08-15       Impact factor: 2.778

7.  Increasing rates of cardiac device infections among Medicare beneficiaries: 1990-1999.

Authors:  Christopher H Cabell; Paul A Heidenreich; Vivian H Chu; Christopher M Moore; Martin E Stryjewski; G Ralph Corey; Vance G Fowler
Journal:  Am Heart J       Date:  2004-04       Impact factor: 4.749

8.  Phenotypic variation of Staphylococcus epidermidis in infection of transvenous endocardial pacemaker electrodes.

Authors:  L M Baddour; L P Barker; G D Christensen; J T Parisi; W A Simpson
Journal:  J Clin Microbiol       Date:  1990-04       Impact factor: 5.948

9.  Sonication of explanted cardiac implants improves microbial detection in cardiac device infections.

Authors:  Alessandra Oliva; Bich Lien Nguyen; Maria T Mascellino; Alessandra D'Abramo; Marco Iannetta; Antonio Ciccaglioni; Vincenzo Vullo; Claudio M Mastroianni
Journal:  J Clin Microbiol       Date:  2012-11-28       Impact factor: 5.948

10.  Small colony variants of Staphylococcus aureus and pacemaker-related infection.

Authors:  Harald Seifert; Hilmar Wisplinghoff; Petra Schnabel; Christof von Eiff
Journal:  Emerg Infect Dis       Date:  2003-10       Impact factor: 6.883

View more
  8 in total

1.  Human transcriptomic response to periprosthetic joint infection.

Authors:  Thao L Masters; Aditya V Bhagwate; Mrunal K Dehankar; Kerryl E Greenwood-Quaintance; Matthew P Abdel; Jay N Mandrekar; Robin Patel
Journal:  Gene       Date:  2022-03-17       Impact factor: 3.688

Review 2.  Approach to Diagnosis of Cardiovascular Implantable-Electronic-Device Infection.

Authors:  Daniel C DeSimone; M Rizwan Sohail
Journal:  J Clin Microbiol       Date:  2018-06-25       Impact factor: 5.948

3.  Detection of Biofilm-associated Implant Pathogens in Cardiac Device Infections: High Sensitivity of Sonication Fluid Culture Even in the Presence of Antimicrobials.

Authors:  Alessandra Oliva; Maria Teresa Mascellino; Bich Lien Nguyen; Massimiliano De Angelis; Alessia Cipolla; Annalisa Di Berardino; Antonio Ciccaglioni; Claudio Maria Mastroianni; Vincenzo Vullo
Journal:  J Glob Infect Dis       Date:  2018 Apr-Jun

4.  Sonication of heart valves detects more bacteria in infective endocarditis.

Authors:  Anna Gomes; Marleen van Oosten; Kasper L B Bijker; Kathleen E Boiten; Elisa N Salomon; Sigrid Rosema; John W A Rossen; Ehsan Natour; Yvonne L Douglas; Greetje A Kampinga; Sander van Assen; Bhanu Sinha
Journal:  Sci Rep       Date:  2018-08-28       Impact factor: 4.379

5.  Predictors of Bloodstream Infection in Patients Presenting With Cardiovascular Implantable Electronic Device Pocket Infection.

Authors:  Zerelda Esquer Garrigos; Merit P George; Sarwat Khalil; Prakhar Vijayvargiya; Omar M Abu Saleh; Paul A Friedman; James M Steckelberg; Daniel C DeSimone; Walter R Wilson; Larry M Baddour; M Rizwan Sohail
Journal:  Open Forum Infect Dis       Date:  2019-02-21       Impact factor: 3.835

Review 6.  Challenges in the Microbiological Diagnosis of Implant-Associated Infections: A Summary of the Current Knowledge.

Authors:  Alessandra Oliva; Maria Claudia Miele; Dania Al Ismail; Federica Di Timoteo; Massimiliano De Angelis; Luigi Rosa; Antimo Cutone; Mario Venditti; Maria Teresa Mascellino; Piera Valenti; Claudio Maria Mastroianni
Journal:  Front Microbiol       Date:  2021-10-29       Impact factor: 5.640

7.  JCS/JHRS 2021 guideline focused update on non-pharmacotherapy of cardiac arrhythmias.

Authors:  Akihiko Nogami; Takashi Kurita; Kengo Kusano; Masahiko Goya; Morio Shoda; Hiroshi Tada; Shigeto Naito; Teiichi Yamane; Masaomi Kimura; Tsuyoshi Shiga; Kyoko Soejima; Takashi Noda; Hiro Yamasaki; Yoshifusa Aizawa; Tohru Ohe; Takeshi Kimura; Shun Kohsaka; Hideo Mitamura
Journal:  J Arrhythm       Date:  2022-01-07

8.  Diagnosis and management of subcutaneous implantable cardioverter-defibrillator infections based on process mapping.

Authors:  Larry M Baddour; Raul Weiss; George E Mark; Mikhael F El-Chami; Mauro Biffi; Vincent Probst; Pier D Lambiase; Marc A Miller; Timothy McClernon; Linda K Hansen; Bradley P Knight
Journal:  Pacing Clin Electrophysiol       Date:  2020-04-23       Impact factor: 1.976

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.