Literature DB >> 25779219

Colorimetric and Fluorescent Bimodal Ratiometric Probes for pH Sensing of Living Cells.

Yuan-Yuan Liu1,2, Ming Wu3, Li-Na Zhu4,5, Xi-Zeng Feng6, De-Ming Kong3,2.   

Abstract

pH measurement is widely used in many fields. Ratiometric pH sensing is an important way to improve the detection accuracy. Herein, five water-soluble cationic porphyrin derivatives were synthesized and their optical property changes with pH value were investigated. Their pH-dependent assembly/disassembly behaviors caused significant changes in both absorption and fluorescence spectra, thus making them promising bimodal ratiometric probes for both colorimetric and fluorescent pH sensing. Different substituent identity and position confer these probes with different sensitive pH-sensing ranges, and the substituent position gives a larger effect. By selecting different porphyrins, different signal intensity ratios and different fluorescence excitation wavelengths, sensitive pH sensing can be achieved in the range of 2.1-8.0. Having demonstrated the excellent reversibility, good accuracy and low cytotoxicity of the probes, they were successfully applied in pH sensing inside living cells.
© 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  colorimetric; fluorescent probes; pH; porphyrins; ratiometric

Mesh:

Substances:

Year:  2015        PMID: 25779219     DOI: 10.1002/asia.201500106

Source DB:  PubMed          Journal:  Chem Asian J        ISSN: 1861-471X


  5 in total

1.  A New Dual-peak Fluorescent Probe for Water Content Detection Made From Taxus.

Authors:  Gang Wang; Yaping Li; Haipeng Chen; Shuqin Tang; Yiyang Cheng; Yuhong Yu; Abdul Qayoom Majeedano; Shangrao Pu; Gang Wang
Journal:  J Fluoresc       Date:  2022-06-30       Impact factor: 2.525

2.  Ultrasonic atomizer based development of pH sensor for real time analysis.

Authors:  Gaurav Pandey; Sandeep Choudhary; Rashmi Chaudhari; Abhijeet Joshi
Journal:  Sci Rep       Date:  2020-07-02       Impact factor: 4.379

3.  Cationic porphyrins with large side arm substituents as resonance light scattering ratiometric probes for specific recognition of nucleic acid G-quadruplexes.

Authors:  Li-Ming Zhang; Yun-Xi Cui; Li-Na Zhu; Jun-Qing Chu; De-Ming Kong
Journal:  Nucleic Acids Res       Date:  2019-04-08       Impact factor: 16.971

4.  pH and Urea Estimation in Urine Samples using Single Fluorophore and Ratiometric Fluorescent Biosensors.

Authors:  Rashmi Chaudhari; Abhijeet Joshi; Rohit Srivastava
Journal:  Sci Rep       Date:  2017-07-19       Impact factor: 4.379

Review 5.  Porphyrins as Colorimetric and Photometric Biosensors in Modern Bioanalytical Systems.

Authors:  Karolis Norvaiša; Marc Kielmann; Mathias O Senge
Journal:  Chembiochem       Date:  2020-03-30       Impact factor: 3.164

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.