Literature DB >> 25775496

A Novel Framework Based on FastICA for High Density Surface EMG Decomposition.

Maoqi Chen, Ping Zhou.   

Abstract

This study presents a progressive FastICA peel-off (PFP) framework for high-density surface electromyogram (EMG) decomposition. The novel framework is based on a shift-invariant model for describing surface EMG. The decomposition process can be viewed as progressively expanding the set of motor unit spike trains, which is primarily based on FastICA. To overcome the local convergence of FastICA, a peel-off strategy, i.e., removal of the estimated motor unit action potential trains from the previous step, is used to mitigate the effects of the already identified motor units, so more motor units can be extracted. A constrained FastICA is applied to assess the extracted spike trains and correct possible erroneous or missed spikes. These procedures work together to improve decomposition performance. The proposed framework was validated using simulated surface EMG signals with different motor unit numbers (30, 70, 91) and SNRs (20, 10, and 0 dB). The results demonstrated relatively large numbers of extracted motor units and high accuracies (high F1-scores). The framework was tested with 111 trials of 64-channel electrode array experimental surface EMG signals during the first dorsal interosseous muscle contraction at different intensities. On average 14.1 ±5.0 motor units were identified from each trial of experimental surface EMG signals.

Entities:  

Mesh:

Year:  2015        PMID: 25775496      PMCID: PMC4567540          DOI: 10.1109/TNSRE.2015.2412038

Source DB:  PubMed          Journal:  IEEE Trans Neural Syst Rehabil Eng        ISSN: 1534-4320            Impact factor:   3.802


  59 in total

1.  Decomposition of multiunit electromyographic signals.

Authors:  J Fang; G C Agarwal; B T Shahani
Journal:  IEEE Trans Biomed Eng       Date:  1999-06       Impact factor: 4.538

2.  A software package for the decomposition of long-term multichannel EMG signals using wavelet coefficients.

Authors:  Daniel Zennaro; Peter Wellig; Volker M Koch; George S Moschytz; Thomas Läubli
Journal:  IEEE Trans Biomed Eng       Date:  2003-01       Impact factor: 4.538

3.  Common input to motor units of digit flexors during multi-digit grasping.

Authors:  Sara A Winges; Marco Santello
Journal:  J Neurophysiol       Date:  2004-07-07       Impact factor: 2.714

Review 4.  Decoding the neural drive to muscles from the surface electromyogram.

Authors:  Dario Farina; Ales Holobar; Roberto Merletti; Roger M Enoka
Journal:  Clin Neurophysiol       Date:  2010-05-04       Impact factor: 3.708

5.  Covariance and time-scale methods for blind separation of delayed sources.

Authors:  Ning Jiang; Dario Farina
Journal:  IEEE Trans Biomed Eng       Date:  2010-10-07       Impact factor: 4.538

6.  Automated decomposition of intramuscular electromyographic signals.

Authors:  Joël R Florestal; Pierre A Mathieu; Armando Malanda
Journal:  IEEE Trans Biomed Eng       Date:  2006-05       Impact factor: 4.538

7.  Estimating motor unit discharge patterns from high-density surface electromyogram.

Authors:  Ales Holobar; Dario Farina; Marco Gazzoni; Roberto Merletti; Damjan Zazula
Journal:  Clin Neurophysiol       Date:  2009-02-08       Impact factor: 3.708

8.  A procedure for decomposing the myoelectric signal into its constituent action potentials--Part II: Execution and test for accuracy.

Authors:  R S LeFever; A P Xenakis; C J De Luca
Journal:  IEEE Trans Biomed Eng       Date:  1982-03       Impact factor: 4.538

9.  Accuracy assessment of CKC high-density surface EMG decomposition in biceps femoris muscle.

Authors:  H R Marateb; K C McGill; A Holobar; Z C Lateva; M Mansourian; R Merletti
Journal:  J Neural Eng       Date:  2011-10-06       Impact factor: 5.379

10.  Motor unit firing pattern of vastus lateralis muscle in type 2 diabetes mellitus patients.

Authors:  Kohei Watanabe; Marco Gazzoni; Ales Holobar; Toshiaki Miyamoto; Kazuhito Fukuda; Roberto Merletti; Toshio Moritani
Journal:  Muscle Nerve       Date:  2013-08-30       Impact factor: 3.217

View more
  20 in total

1.  ICA-based muscle-tendon units localization and activation analysis during dynamic motion tasks.

Authors:  Xiang Chen; Shaoping Wang; Chengjun Huang; Shuai Cao; Xu Zhang
Journal:  Med Biol Eng Comput       Date:  2017-07-18       Impact factor: 2.602

2.  Motor unit number estimation based on high-density surface electromyography decomposition.

Authors:  Yun Peng; Jinbao He; Bo Yao; Sheng Li; Ping Zhou; Yingchun Zhang
Journal:  Clin Neurophysiol       Date:  2016-06-25       Impact factor: 3.708

3.  Automatic Multichannel Intramuscular Electromyogram Decomposition: Progressive FastICA Peel-Off and Performance Validation.

Authors:  Maoqi Chen; Xu Zhang; Ping Zhou
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2018-11-20       Impact factor: 3.802

4.  A Novel Validation Approach for High-Density Surface EMG Decomposition in Motor Neuron Disease.

Authors:  Maoqi Chen; Xu Zhang; Ping Zhou
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2018-06       Impact factor: 3.802

5.  Impact of parameter selection on estimates of motoneuron excitability using paired motor unit analysis.

Authors:  Altamash Hassan; Christopher K Thompson; Francesco Negro; Mark Cummings; Randall K Powers; C J Heckman; Julius P A Dewald; Laura Miller McPherson
Journal:  J Neural Eng       Date:  2020-02-18       Impact factor: 5.379

Review 6.  Endurance-exercise training adaptations in spinal motoneurones: potential functional relevance to locomotor output and assessment in humans.

Authors:  Kevin E Power; Evan J Lockyer; Alberto Botter; Taian Vieira; Duane C Button
Journal:  Eur J Appl Physiol       Date:  2022-02-28       Impact factor: 3.078

7.  Estimates of persistent inward currents in tibialis anterior motor units during standing ramped contraction tasks in humans.

Authors:  Obaid U Khurram; Francesco Negro; C J Heckman; Christopher K Thompson
Journal:  J Neurophysiol       Date:  2021-06-16       Impact factor: 2.974

Review 8.  Properties of the surface electromyogram following traumatic spinal cord injury: a scoping review.

Authors:  Gustavo Balbinot; Guijin Li; Matheus Joner Wiest; Maureen Pakosh; Julio Cesar Furlan; Sukhvinder Kalsi-Ryan; Jose Zariffa
Journal:  J Neuroeng Rehabil       Date:  2021-06-29       Impact factor: 4.262

9.  FastICA peel-off for ECG interference removal from surface EMG.

Authors:  Maoqi Chen; Xu Zhang; Xiang Chen; Mingxing Zhu; Guanglin Li; Ping Zhou
Journal:  Biomed Eng Online       Date:  2016-06-13       Impact factor: 2.819

10.  Model-Based Analysis of Muscle Strength and EMG-Force Relation with respect to Different Patterns of Motor Unit Loss.

Authors:  Chengjun Huang; Maoqi Chen; Yingchun Zhang; Sheng Li; Ping Zhou
Journal:  Neural Plast       Date:  2021-06-22       Impact factor: 3.599

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.