Literature DB >> 25770607

Inhibitive potentiometric detection of trace metals with ultrathin polypyrrole glucose oxidase biosensor.

Joseph G Ayenimo1, Samuel B Adeloju2.   

Abstract

A method, based on the inhibition of an ultrathin polypyrrole-glucose oxidase (PPy-GOx) potentiometric biosensor response, is described for the detection of Cu(2+), Hg(2+), Cd(2+) and Pb(2+) ions. Based on experimental conditions (0.2 M pyrrole, 500 U mL(-1) GOx, and an applied current density of 0.05 mA cm(-2) and a polymerization period of 500s) previously published by us, PPy-GOx films of approximately 55 nm thick were used to demonstrate the inhibitive potentiometric detection of selected trace metals down to 0.079 μM Cu(2+), 0.025 μM Hg(2+), 0.024 μM Pb(2+) and 0.044 μM Cd(2+). Furthermore, good linear concentration ranges were achieved for Cu(2+) (0.079-16 μM), Hg(2+) (0.025-5 μM), Pb(2+) (0.10-15 μM) and Cd(2+) (0.04-62 μM). The analysis of the nature of the inhibition of glucose oxidase in the PPy-GOx biosensor by these metals was achieved by Dixon and Cornish-Bowden plots. The shapes of the curves (exponential decay, parabolic and linear) obtained for the inhibitors suggest that the inhibition by the metal ions may not be exclusively directed at the essential -SH group, but involve additional binding sites of the enzyme. Dixon and Cornish-Bowden plots suggest that the inhibition is competitive for Cd(2+), while non-competitive inhibition was observed for other metal ions. The ultra-thin PPy-GOx film enabled improved permeability to the metal inhibitors than possible with conventional biosensors with thicker films and, hence, better reflects the actual inhibition effect of the trace metals on the enzyme activity. The use of the ultra-thin film also eliminated the usual need for incubation of the enzyme electrode for a long period in the presence of the inhibitors. Furthermore, a rapid recovery of the enzyme activity was achieved by simply washing the electrode with water and storing in phosphate buffer for 10-15 min. The proposed biosensing approach was successfully used for the detection of individual trace metals in tap water, achieving a 98-101% recovery.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Biosensor; Glucose oxidase; Inhibition; Potentiometry; Trace metals; Ultrathin polypyrrole film

Mesh:

Substances:

Year:  2015        PMID: 25770607     DOI: 10.1016/j.talanta.2015.01.006

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Peripheral Nerve Regeneration Strategies: Electrically Stimulating Polymer Based Nerve Growth Conduits.

Authors:  Matthew Anderson; Namdev B Shelke; Ohan S Manoukian; Xiaojun Yu; Louise D McCullough; Sangamesh G Kumbar
Journal:  Crit Rev Biomed Eng       Date:  2015

Review 2.  Recent advances in rapid pathogen detection method based on biosensors.

Authors:  Ying Chen; Zhenzhen Wang; Yingxun Liu; Xin Wang; Ying Li; Ping Ma; Bing Gu; Hongchun Li
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2018-03-22       Impact factor: 3.267

Review 3.  From Electrochemical Biosensors to Biomimetic Sensors Based on Molecularly Imprinted Polymers in Environmental Determination of Heavy Metals.

Authors:  Cosimino Malitesta; Sabrina Di Masi; Elisabetta Mazzotta
Journal:  Front Chem       Date:  2017-07-06       Impact factor: 5.221

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.