Literature DB >> 25766811

Electrochemical fabrication of polymerized imidazole-based ionic liquid bearing pyrrole moiety for sensitive determination of hexestrol in chicken meat.

Xuemin Chen1, Yanhui Ma1, Danchao Chen2, Ming Ma2, Chunya Li3.   

Abstract

1-[3-(tert-Butoxycarbonylamino)propyl]-3-[3-(N-pyrrole)propyl]imidazolium tetrafluoroborate [(t-Boc-APPPI)BF4], which is a novel pyrrolyl-functionalized ionic liquid, was synthesized and characterized. Subsequently, it was electrochemically deposited onto a glassy carbon electrode surface to fabricate a polymerized ionic liquid film electrode. X-ray photoelectron spectroscopy, scanning electron microscope and electrochemical impedance spectroscopy were used to confirm the successful polymerization of ionic liquid. Voltammetric behaviors of hexestrol at the film electrode were investigated. The oxidation peak slightly shifted towards positive potential, however, dramatically increased in peak current. Experimental conditions for hexestrol determination were optimized. The oxidation peak current is linear with hexestrol concentration in the range of 1.0 × 10(-8)-1.0 × 10(-5) mol L(-1). The detection limit is estimated to be 2.1 × 10(-9) mol L(-1) (S/N=3). Hexestrol in chicken meat was determined using the film electrode with good accuracy.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Chicken meat; Electropolymerization; Hexestrol; Polymerized ionic liquid

Mesh:

Substances:

Year:  2015        PMID: 25766811     DOI: 10.1016/j.foodchem.2015.02.038

Source DB:  PubMed          Journal:  Food Chem        ISSN: 0308-8146            Impact factor:   7.514


  3 in total

1.  A glassy carbon electrode modified with silver nanoparticles and functionalized multi-walled carbon nanotubes for voltammetric determination of the illicit growth promoter dienestrol in animal urine.

Authors:  Manoel M S Lima Filho; Alessandra A Correa; Francisco D C Silva; Francisco A O Carvalho; Lúcia H Mascaro; Thiago M B F Oliveira
Journal:  Mikrochim Acta       Date:  2019-07-10       Impact factor: 5.833

2.  Development of Ionic Liquid Modified Disposable Graphite Electrodes for Label-Free Electrochemical Detection of DNA Hybridization Related to Microcystis spp.

Authors:  Ceren Sengiz; Gulsah Congur; Arzum Erdem
Journal:  Sensors (Basel)       Date:  2015-09-09       Impact factor: 3.576

3.  Hexestrol Deteriorates Oocyte Quality via Perturbation of Mitochondrial Dynamics and Function.

Authors:  Dong Niu; Kun-Lin Chen; Yi Wang; Xiao-Qing Li; Lu Liu; Xiang Ma; Xing Duan
Journal:  Front Cell Dev Biol       Date:  2021-07-06
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.