Literature DB >> 25766727

Comparison of automated breast ultrasonography to handheld ultrasonography in detecting and diagnosing breast lesions.

Su Kyung Jeh1, Sung Hun Kim2, Jae Jeong Choi1, Sang Sul Jung3, Byung Joo Choe3, Sarah Park4, Mi Sun Park5.   

Abstract

BACKGROUND: Automated breast ultrasonography (ABUS) is increasingly used as a screening tool. Several studies have demonstrated a similar diagnostic performance for ABUS compared with handheld ultrasonography (HHUS), but the overall results have been controversial.
PURPOSE: To compare the clinical utility of ABUS and HHUS for detection and diagnosis of breast lesions.
MATERIAL AND METHODS: ABUS and HHUS images of suspicious breast lesions were obtained for 173 consecutive women scheduled to undergo ultrasonography (US)-guided or stereotactic biopsy. There were a total of 206 lesions, 46 of which were malignant and 160 benign. Three breast radiologists took part in this study: two reviewed the ABUS images, and the third reviewed all of the images, ABUS and HHUS, as well as the patients' medical records. The biopsied-lesion-detection rates were obtained. Using the Breast Imaging Reporting and Data System (BI-RADS), the images of the biopsied lesions were evaluated. Factors affecting ABUS detectability were analyzed.
RESULTS: The overall detection rates were 83.0% for ABUS and 94.2% for HHUS. Ten lesions were not detected on either HHUS or ABUS and these were microcalcifications (one malignancy and nine benign lesions). Of the 194 HHUS-detected lesions, 169 were detected by ABUS and 25 benign were not. ABUS less frequently detected lesions of smaller size as well as those of benign appearance and lower final-assessment category (P = 0.011 and P < 0.0001, respectively).
CONCLUSION: ABUS detected all of the malignant lesions that were detected on HHUS. ABUS missed several smaller benign lesions. © The Foundation Acta Radiologica 2015.

Entities:  

Keywords:  Ultrasonography; breast; diagnosis; early detection of cancer; mammary

Mesh:

Year:  2015        PMID: 25766727     DOI: 10.1177/0284185115574872

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  11 in total

1.  The Role of ABUS in The Diagnosis of Breast Cancer.

Authors:  Elżbieta Łuczyńska; Marta Pawlak; Tadeusz Popiela; Wojciech Rudnicki
Journal:  J Ultrason       Date:  2022-04-27

2.  Preliminary study of the technical limitations of automated breast ultrasound: from procedure to diagnosis.

Authors:  Maria Julia Gregório Calas; Fernanda Philadelpho Arantes Pereira; Leticia Pereira Gonçalves; Flávia Paiva Proença Lobo Lopes
Journal:  Radiol Bras       Date:  2020 Sep-Oct

3.  SOFIA: A Novel Automated Breast Ultrasound System Used on Patients in the Prone Position: A Pilot Study on Lesion Detection in Comparison to Handheld Grayscale Ultrasound.

Authors:  André Farrokh; Harika Erdönmez; Fritz Schäfer; Nicolai Maass
Journal:  Geburtshilfe Frauenheilkd       Date:  2018-06-04       Impact factor: 2.915

Review 4.  Automatic breast ultrasound: state of the art and future perspectives.

Authors:  Luca Nicosia; Federica Ferrari; Anna Carla Bozzini; Antuono Latronico; Chiara Trentin; Lorenza Meneghetti; Filippo Pesapane; Maria Pizzamiglio; Nicola Balesetreri; Enrico Cassano
Journal:  Ecancermedicalscience       Date:  2020-06-23

5.  Ultrasound for Breast Cancer Detection Globally: A Systematic Review and Meta-Analysis.

Authors:  Rupali Sood; Anne F Rositch; Delaram Shakoor; Emily Ambinder; Kara-Lee Pool; Erica Pollack; Daniel J Mollura; Lisa A Mullen; Susan C Harvey
Journal:  J Glob Oncol       Date:  2019-08

6.  False-negative results on computer-aided detection software in preoperative automated breast ultrasonography of breast cancer patients.

Authors:  Youngjune Kim; Jiwon Rim; Sun Mi Kim; Bo La Yun; So Yeon Park; Hye Shin Ahn; Bohyoung Kim; Mijung Jang
Journal:  Ultrasonography       Date:  2020-03-24

7.  Dependability of Automated Breast Ultrasound (ABUS) in Assessing Breast Imaging Reporting and Data System (BI-RADS) Category and Size of Malignant Breast Lesions Compared with Handheld Ultrasound (HHUS) and Mammography (MG).

Authors:  He Chen; Ming Han; Hui Jing; Zhao Liu; Haitao Shang; Qiucheng Wang; Wen Cheng
Journal:  Int J Gen Med       Date:  2021-12-01

8.  Re-evaluation of high-risk breast mammography lesions by target ultrasound and ABUS of breast non-mass-like lesions.

Authors:  Jianxing Zhang; Lishang Cai; Ling Chen; Xiyan Pang; Miao Chen; Dan Yan; Jia Liu; Liangping Luo
Journal:  BMC Med Imaging       Date:  2021-10-26       Impact factor: 1.930

9.  Diagnostic value of an automated breast volume scanner compared with a hand-held ultrasound: a meta-analysis.

Authors:  Xiaohui Zhang; Juan Chen; Yidong Zhou; Feng Mao; Yan Lin; Songjie Shen; Qiang Sun; Zhaolian Ouyang
Journal:  Gland Surg       Date:  2019-12

10.  Breast ultrasound: automated or hand-held? Exploring patients' experience and preference.

Authors:  Ilaria Mussetto; Licia Gristina; Simone Schiaffino; Simona Tosto; Edoardo Raviola; Massimo Calabrese
Journal:  Eur Radiol Exp       Date:  2020-02-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.