| Literature DB >> 25762832 |
C de Crea1, M Raffaelli1, D Maccora1, C Carrozza2, G Canu2, G Fadda3, R Bellantone1, C P Lombardi1.
Abstract
Ultrasound-guided fine-needle aspiration biopsy cytology (FNAB-C) is able to detect approximately 63% of medullary thyroid carcinoma (MTC). The measurement of calcitonin in the needle washout (FNAB-CT) could improve its accuracy. Sixty-two FNAB-C were performed in 38 patients. Serum calcitonin (sCT) was measured before performing FNAB-C. After obtaining a FNAB-C specimen, the needle was washed with 0.5 ml of saline solution to obtain the CT washouts. Receiver operating characteristic (RO C) analysis identified the cut-offs of FNAB-CT and FNAB-CT/sCT. Eighteen MTC were found at final histology. RO C analysis indicated FNAB-CT > 10.4 pg/ml and FNABCT/ sCT > 1.39 as more accurate cut-off values. Overall accuracy, positive (PPV) and negative predictive values (NPV) were 85%, 100 and 83%, respectively, for FNAB-C, 97%, 100%, 96% for FNAB-CT and 90%, 83% and 93% for FNAB-CT/sCT. The integration of FNAB-C and FNAB-CT resulted in 98% overall accuracy, 100% PPV and 98% NPV; the integration of FNAB-C and FNAB-CT/sCT in 90% overall accuracy, 80% PPV and 95% NPV. One of 2 false negative FNAB-CT and one of 3 false negative FNAB CT/sCT were correctly diagnosed by FNAB-C. Eight of 9 non-diagnostic FNAB-C were correctly classified by FNAB-CT and 7 by FNAB CT/sCT. FNAB-CT should integrate but not replace FNAB-C. FNAB-CT is particularly useful in the presence of non-diagnostic FNAB-C.Entities:
Keywords: Calcitonin; Cytology; Lymph node metastases; Medullary thyroid carcinoma; US-guided fine-needle aspiration biopsy
Mesh:
Substances:
Year: 2014 PMID: 25762832 PMCID: PMC4346997
Source DB: PubMed Journal: Acta Otorhinolaryngol Ital ISSN: 0392-100X Impact factor: 2.124
Results of FNAB-C, FNAB-CT, FNAB-CT/sCT ratio, and integration of FNAB-C with FNAB-CT and FNAB-CT/sCT ratio compared with histology.
| Positive for MTC | Negative for MTC | |
|---|---|---|
| FNAB-C | 9 | 53 |
| FNAB-CT | 16 | 46 |
| FNAB-CT | 15 | 41 |
| FNAB-C | 17 | 44 |
| FNAB-C | 16 | 40 |
FNAB-C: ultrasound-guided fine-needle aspiration biopsy cytology;
FNAB-CT: calcitonin in the needle wash-out;
sCT: serum calcitonin;
MTC: medullary thyroid carcinoma.
Fig. 1.ROC* curve of FNAB-CT†.
Cut-off = 10.4 pg/ml; sensitivity 89%; specificity 100%; PPV‡ 100%; NPV¶ 96%; accuracy 97%; AUC** = 0.99 (CI†† = 95%, 0.93 - 1.00).
* ROC: Receiver Operating Characteristic; † FNAB-CT: calcitonin in the needle wash-out; ‡ PPV: positive predictive value; ¶ NPV: negative predictive value; ** AUC: area under curve; †† CI: confidence interval
Fig. 2.ROC* curve of the FNAB-CT†/sCT‡ ratio.
Cut-off ratio = 1.39; sensitivity 83%; specificity 93%; PPV¶ 83%; NPV** 93%; accuracy 90%; AUC†† = 0.90 (CI‡‡ = 95%, 0.80 - 0.96).
* ROC: Receiver Operating Characteristic; † FNAB-CT: calcitonin in the needle wash-out; ‡ sCT: serum calcitonin; ¶ PPV: positive predictive value; ** NPV: negative predictive value; †† AUC: area under curve; ‡‡ CI: confidence interval.
Accuracy, positive predictive value and negative predictive value of FNAB-C, FNAB-CT, FNAB-CT/sCT ratio, and integration of FNAB-C with FNAB-CT and FNAB-CT/sCT.
| Sensitivity | Specificity | Accuracy | Positive predictive value | Negative predictive value | |
|---|---|---|---|---|---|
| FNAB-C | 50% | 100% | 85% | 100% | 83% |
| FNAB-CT | 89% | 100% | 97% | 100% | 96% |
| FNAB-CT | 83% | 93% | 90% | 83% | 93% |
| FNAB-C | 94% | 100% | 98% | 100% | 98% |
| FNAB-C | 89% | 91% | 90% | 80% | 95% |
FNAB-C: ultrasound-guided fine-needle aspiration biopsy cytology;
FNAB-CT: calcitonin in the needle wash-out;
sCT: serum calcitonin.