Literature DB >> 25760510

A novel technique using sensor-based technology to evaluate tibial tray rotation.

Martin W Roche, Leah C Elson, Christopher R Anderson.   

Abstract

Rotational tibiofemoral congruency and centralized patellar tracking are critical technical factors that affect the postoperative success of total knee arthroplasty (TKA). Several techniques are used to position the femoral component, but there is no validated method for achieving the ideal rotational position of the tibial component. It has been suggested that referencing the midmedial third of the tibial tubercle intraoperatively mitigates positional outliers. This study used data collected from intraoperative sensors to quantify the variability associated with using the midmedial third of the tibial tubercle in 170 patients undergoing primary TKA. With the sensor-equipped trial insert in place, the knee was taken into extension and the location of the femoral condylar contact point on the articular surface of the tibial insert was displayed. Rotational adjustments of the tibial tray were evaluated in real time as the surgeon corrected tray malpositioning. The initial and final angles of tibial tray rotation were captured and recorded with intraoperative video feed. When referencing the tubercle, 53% of patients had asymmetric tibiofemoral congruency in extension. Of those patients, 68% had excessive internal rotation of the tibial tray relative to the femur and 32% had excessive external rotation. The average tibiofemoral incongruency deviated from a neutral position by 6° (range, 0.5°-19.2°). Data from this evaluation suggest that use of the tibial tubercle to maximize tibiofemoral congruency is highly variable and inconsistent for confirming the final rotation of the tibial tray. Copyright 2015, SLACK Incorporated.

Entities:  

Mesh:

Year:  2015        PMID: 25760510     DOI: 10.3928/01477447-20150305-60

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  2 in total

1.  Algorithmic pie-crusting of the medial collateral ligament guided by sensing technology affects the use of constrained inserts during total knee arthroplasty.

Authors:  Spencer Amundsen; Yuo-Yu Lee; Alejandro González Della Valle
Journal:  Int Orthop       Date:  2017-02-10       Impact factor: 3.075

Review 2.  A Systematic Literature Review of Three Modalities in Technologically Assisted TKA.

Authors:  William A Leone; Leah C Elson; Christopher R Anderson
Journal:  Adv Orthop       Date:  2015-11-18
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.