Effect of longer battery life on small bowel capsule endoscopy.

George Ou1, Neal Shahidi1, Cherry Galorport1, Oliver Takach1, Terry Lee1, Robert Enns1.   

Abstract

AIM: To determine if longer battery life improves capsule endoscopy (CE) completion rates.
METHODS: A retrospective study was performed at a tertiary, university-affiliated hospital in Vancouver, Canada. Patients who underwent CE with either PillCam™ SB2 or SB2U between 01/2010 and 12/2013 were considered for inclusion. SB2 and SB2U share identical physical dimensions but differ in their battery lives (8 h vs 12 h). Exclusion criteria included history of gastric or small bowel surgery, endoscopic placement of CE, interrupted view of major landmarks due to technical difficulty or significant amount of debris, and repeat CE using same system. Basic demographics, comorbidities, medications, baseline bowel habits, and previous surgeries were reviewed. Timing of major landmarks in CE were recorded, and used to calculate gastric transit time, small bowel transit time, and total recording time. A complete CE study was defined as visualization of cecum. Transit times and completion rates were compared.
RESULTS: Four hundred and eight patients, including 208 (51.0%) males, were included for analysis. The mean age was 55.5 ± 19.3 years. The most common indication for CE was gastrointestinal bleeding (n = 254, 62.3%), followed by inflammatory bowel disease (n = 86, 21.1%). There was no difference in gastric transit times (group difference 0.90, 95%CI: 0.72-1.13, P = 0.352) and small bowel transit times (group difference 1.07, 95%CI: 0.95-1.19, P = 0.261) between SB2U and SB2, but total recording time was about 14% longer in the SB2U group (95%CI: 10%-18%, P < 0.001) and there was a corresponding trend toward higher completion rate (88.2% vs 93.2%, OR = 1.78, 95%CI 0.88-3.63, P = 0.111). There was no statistically significant difference in the rates of positive findings (OR = 0.98, 95%CI: 0.64-1.51, P = 0.918).
CONCLUSION: Extending the operating time of CE may be a simple method to improve completion rate although it does not affect the rate of positive findings.

Entities:  

Keywords:  Battery life; Capsule endoscopy; Completion rate; Positive finding; Transit time

Mesh:

Year:  2015        PMID: 25759536      PMCID: PMC4351218          DOI: 10.3748/wjg.v21.i9.2677

Source DB:  PubMed          Journal:  World J Gastroenterol        ISSN: 1007-9327            Impact factor:   5.742


  27 in total

1.  Transit times in capsule endoscopy: are all patients the same?

Authors:  R Enns
Journal:  Dig Liver Dis       Date:  2007-04-24       Impact factor: 4.088

Review 2.  Do prokinetics influence the completion rate in small-bowel capsule endoscopy? A systematic review and meta-analysis.

Authors:  Anastasios Koulaouzidis; Andry Giannakou; Diana E Yung; Konstantinos J Dabos; John N Plevris
Journal:  Curr Med Res Opin       Date:  2013-07-11       Impact factor: 2.580

3.  The effect of chewing gum on small-bowel transit time in capsule endoscopy: a prospective, randomized trial.

Authors:  George Ou; Sigrid Svarta; Calvin Chan; Cherry Galorport; Hong Qian; Robert Enns
Journal:  Gastrointest Endosc       Date:  2013-10-07       Impact factor: 9.427

4.  Prospective controlled study on the effects of polyethylene glycol in capsule endoscopy.

Authors:  Takafumi Ito; Ken Ohata; Akiko Ono; Hideyuki Chiba; Yosuke Tsuji; Hajime Sato; Nobuyuki Matsuhashi
Journal:  World J Gastroenterol       Date:  2012-04-21       Impact factor: 5.742

Review 5.  Indications and detection, completion, and retention rates of small-bowel capsule endoscopy: a systematic review.

Authors:  Zhuan Liao; Rui Gao; Can Xu; Zhao-Shen Li
Journal:  Gastrointest Endosc       Date:  2010-02       Impact factor: 9.427

Review 6.  Role of capsule endoscopy in inflammatory bowel disease.

Authors:  Uri Kopylov; Ernest G Seidman
Journal:  World J Gastroenterol       Date:  2014-02-07       Impact factor: 5.742

7.  Risk factors for incomplete small-bowel capsule endoscopy.

Authors:  Jessie Westerhof; Rinse K Weersma; Jan J Koornstra
Journal:  Gastrointest Endosc       Date:  2008-08-08       Impact factor: 9.427

8.  First clinical trial of a newly developed capsule endoscope with panoramic side view for small bowel: a pilot study.

Authors:  Kilian Friedrich; Sven Gehrke; Wolfgang Stremmel; Andreas Sieg
Journal:  J Gastroenterol Hepatol       Date:  2013-09       Impact factor: 4.029

Review 9.  Should bowel preparation, antifoaming agents, or prokinetics be used before video capsule endoscopy? A systematic review and meta-analysis.

Authors:  Vikram S Kotwal; Bashar M Attar; Saurabh Gupta; Rajender Agarwal
Journal:  Eur J Gastroenterol Hepatol       Date:  2014-02       Impact factor: 2.566

10.  Guidelines for Bowel Preparation before Video Capsule Endoscopy.

Authors:  Hyun Joo Song; Jeong Seop Moon; Jae Hyuk Do; In Hye Cha; Chang Hun Yang; Myung-Gyu Choi; Yoon Tae Jeen; Hyun Jung Kim
Journal:  Clin Endosc       Date:  2013-03-31
View more
  11 in total

Review 1.  Bleeding Lesion of the Small Bowel: an Extensive Update Leaving No Stone Unturned.

Authors:  Cedric Van de Bruaene; Pieter Hindryckx; Laurens Van de Bruaene; Danny De Looze
Journal:  Curr Gastroenterol Rep       Date:  2018-03-07

2.  Sham Feeding with Bacon Does Not Alter Transit Time or Complete Examination Rate During Small Bowel Capsule Endoscopy.

Authors:  David Prichard; George Ou; Cherry Galorport; Robert Enns
Journal:  Dig Dis Sci       Date:  2018-01-04       Impact factor: 3.199

Review 3.  Optimising the performance and interpretation of small bowel capsule endoscopy.

Authors:  Sabina Beg; Adolfo Parra-Blanco; Krish Ragunath
Journal:  Frontline Gastroenterol       Date:  2017-11-16

Review 4.  What defines quality in small bowel capsule endoscopy.

Authors:  Ioannis V Mitselos; Dimitrios K Christodoulou
Journal:  Ann Transl Med       Date:  2018-07

Review 5.  Gastrointestinal diagnosis using non-white light imaging capsule endoscopy.

Authors:  Gerard Cummins; Benjamin F Cox; Gastone Ciuti; Thineskrishna Anbarasan; Marc P Y Desmulliez; Sandy Cochran; Robert Steele; John N Plevris; Anastasios Koulaouzidis
Journal:  Nat Rev Gastroenterol Hepatol       Date:  2019-07       Impact factor: 46.802

6.  Adverse events of video capsule endoscopy over the past two decades: a systematic review and proportion meta-analysis.

Authors:  Yuan-Chen Wang; Jun Pan; Ya-Wei Liu; Feng-Yuan Sun; Yang-Yang Qian; Xi Jiang; Wen-Bin Zou; Ji Xia; Bin Jiang; Nan Ru; Jia-Hui Zhu; En-Qiang Linghu; Zhao-Shen Li; Zhuan Liao
Journal:  BMC Gastroenterol       Date:  2020-11-02       Impact factor: 3.067

7.  Can domperidone decrease transit time of pediatric video capsule endoscopy? A randomized controlled trial.

Authors:  Jie Wu; Ziqing Ye; Aijuan Xue; Ying Huang
Journal:  Transl Pediatr       Date:  2021-02

Review 8.  Contrast-Enhanced Cross Sectional Imaging and Capsule Endoscopy: New Perspectives for a Whole Picture of the Small Bowel.

Authors:  Pedro Boal Carvalho; José Cotter
Journal:  GE Port J Gastroenterol       Date:  2015-09-01

9.  Role of video capsule endoscopy in patients with constitutional mismatch repair deficiency (CMMRD) syndrome: report from the International CMMRD Consortium.

Authors:  Y Shimamura; C M Walsh; S Cohen; M Aronson; U Tabori; P P Kortan; C A Durno
Journal:  Endosc Int Open       Date:  2018-08-10

Review 10.  A Current and Newly Proposed Artificial Intelligence Algorithm for Reading Small Bowel Capsule Endoscopy.

Authors:  Dong Jun Oh; Youngbae Hwang; Yun Jeong Lim
Journal:  Diagnostics (Basel)       Date:  2021-06-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.