Literature DB >> 25757106

Reconstitution fluid type does not affect pulmonary inflammation or DNA damage following infusion of lyophilized plasma.

Sean P McCully1, Tim H Lee, Belinda H McCully, Claire L Sands, Elizabeth A Rick, Rondi K Dean, Nathan W Anderson, David A Hampton, Scott G Louis, Jerome A Differding, Martin A Schreiber.   

Abstract

BACKGROUND: Dysfunctional inflammation following traumatic hemorrhage can lead to multiple-organ failure and death. In our polytrauma swine model, lyophilized plasma (LP) reconstituted with sterile water and ascorbic acid suppressed systemic inflammation and attenuated DNA damage. However, it remains unknown whether the inflammatory response is affected by the type of fluid used to reconstitute LP. We hypothesized that common resuscitation fluids such as normal saline (LP-NS), lactated Ringer's solution (LP-LR), Hextend (LP-HX), or sterile water (LP-SW) would yield similar inflammation profiles and DNA damage following LP reconstitution and transfusion.
METHODS: This was a randomized, prospective, blinded animal study. LP was reconstituted to 50% of original volume with NS, LR, HX, or SW buffered with 15-mM ascorbic acid. Forty swine were subjected to a validated model of polytrauma, hemorrhagic shock, and Grade V liver injury and resuscitated with LP. Serum interleukin 6 (IL-6), IL-10, plasma C-reactive protein, and 8-hydroxy-2-deoxyguanosine concentrations were assessed for systemic inflammation and DNA damage at baseline, 2 hours, and 4 hours following liver injury. Lung inflammation was evaluated by Real Time Polymerize Chain Reaction (RT-PCR).
RESULTS: Reconstituted LP pH was similar between groups before resuscitation. IL-6 and IL-10 increased at 2 hours and 4 hours compared with baseline in all groups (p < 0.017). DNA damage increased at 2 hours and 4 hours compared with baseline and from 2 hours to 4 hours in the LP-NS, LP-LR, and LP-SW groups (all p < 0.017). Animals resuscitated with LP-HX not only demonstrated increased DNA damage at 4 hours versus baseline but also had the lowest C-reactive protein level at 2 hours and 4-hours (p < 0.017). Overall, differences between groups were similar for DNA damage and lung inflammation.
CONCLUSION: Reconstitution fluid type does not affect inflammatory cytokine profiles or DNA damage following LP transfusion in this swine polytrauma model. Based on universal availability, these data suggest that sterile water is the most logical choice for LP reconstitution in humans. LEVEL OF EVIDENCE: Prognostic, level II.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25757106     DOI: 10.1097/TA.0000000000000524

Source DB:  PubMed          Journal:  J Trauma Acute Care Surg        ISSN: 2163-0755            Impact factor:   3.313


  1 in total

1.  Temporal profile of the pro- and anti-inflammatory responses to severe hemorrhage in patients with venous thromboembolism: Findings from the PROPPR trial.

Authors:  Belinda H McCully; Charlie E Wade; Erin E Fox; Kenji Inaba; Mitchell J Cohen; John B Holcomb; Martin A Schreiber
Journal:  J Trauma Acute Care Surg       Date:  2021-05-01       Impact factor: 3.697

  1 in total