Literature DB >> 25756655

Mechanical properties of mosquito nets in the context of hernia repair.

Andrzej Ambroziak1, Katarzyna Szepietowska1, Izabela Lubowiecka1.   

Abstract

The paper deals with issue of applying mosquito nets as implants in hernia repair, which have already been used in resource-poor developing countries. Uniaxial tensile tests have been conducted on polyester mosquito meshes in two orthogonal directions. Non-linear elastic constitutive laws parameters have been identified to be applied in dense net material models. Mechanical performance of tested mosquito nets has been compared with properties of commercial implants used in treatment of hernia and with properties of human tissue. This study contributes to mechanical knowledge of hernia repair issue by investigation of cheaper alternative to commercial implants.

Entities:  

Keywords:  Murnaghan model; dense net model; hernia implants; mechanical properties; mosquito net; tensile test

Mesh:

Substances:

Year:  2015        PMID: 25756655     DOI: 10.1080/10255842.2015.1016004

Source DB:  PubMed          Journal:  Comput Methods Biomech Biomed Engin        ISSN: 1025-5842            Impact factor:   1.763


  1 in total

Review 1.  A systematic review and meta-analysis of the post-operative adverse effects associated with mosquito net mesh in comparison to commercial hernia mesh for inguinal hernia repair in low income countries.

Authors:  T Patterson; P Currie; S Patterson; P Patterson; C Meek; R McMaster
Journal:  Hernia       Date:  2017-04-13       Impact factor: 4.739