| Literature DB >> 25756048 |
Berkan Celikten1, Ceren Feriha Uzuntas1, Kamran Gulsahi2.
Abstract
The aim of this study was to compare the vertical fracture resistance of roots obturated with different root canal filling materials and sealers. Crowns of 55 extracted mandibular premolar teeth were removed to provide root lengths of 13 mm. Five roots were saved as negative control group (canals unprepared and unfilled). Fifty root canals were instrumented and then five roots were saved as positive control group (canals prepared but unfilled). The remaining 45 roots were randomly divided into three experimental groups (n = 15 root/group) and obturated with the following procedures: in group 1, glass ionomer-based sealer and cone (ActiV GP obturation system); in group 2, bioceramic sealer and cone (EndoSequence BC obturation system); and in group 3, roots were filled with bioceramic sealer and cone (Smartpaste bio obturation system). All specimens were tested in a universal testing machine for measuring fracture resistance. For each root, the force at the time of fracture was recorded in Newtons. The statistical analysis was performed by using Kruskal-Wallis and post hoc test. There were no significant differences between the three experimental groups. The fracture values of three experimental and negative control groups were significantly higher than the positive control group. Within the limitations of this study, all materials increased the fracture resistance of instrumented roots.Entities:
Mesh:
Substances:
Year: 2015 PMID: 25756048 PMCID: PMC4337756 DOI: 10.1155/2015/591031
Source DB: PubMed Journal: Biomed Res Int Impact factor: 3.411
Compositions of obturation materials used in this study.
| Obturation material | Composition |
|---|---|
| ActiV GP sealer | Powder: barium alimunasilicate glass powder, dried polyacrylic acid |
|
| |
| ActiV GP cone | Glass ionomer-coated gutta-percha (2 |
|
| |
| Endosequence BC Sealer | Zirconium oxide, calcium silicates, calcium phosphate monobasic, calcium hydroxide, filler and thickening agents |
|
| |
| Endosequence BC point | Coating each cone with bioceramic nanoparticles. |
|
| |
| Smartpaste bio | Zirconium oxide, tricalcium silicate, dicalcium silicate, calcium hydroxide, filler and thickening agents |
|
| |
| Smartpaste bio propoint | Radiopaque core coated with a hydrophilic polymer |
Mean ± standard deviation, 95% Confidence Interval, median, and maximum and minimum values of fracture strength for each group (in Newtons).
| Groups |
| Mean ± SD | 95% Confidence Interval | Median | Max | Min | |
|---|---|---|---|---|---|---|---|
| Lower bound | Upper bound | ||||||
| ActiV GP sealer + GP cone | 15 | 698.6 ± 212.8a,b | 580.7 | 816.5 | 708.7 | 1087.2 | 377.4 |
| EndoSequence BC sealer + BC point | 15 | 580.8 ± 109.6a | 520.1 | 641.5 | 571.4 | 883.4 | 454.1 |
| Smartpaste bio sealer + Propoint | 15 | 599.1 ± 174.6a | 502.4 | 695.8 | 588.0 | 947.2 | 368.5 |
| negative control | 5 | 831.9 ± 143.7b | 653.5 | 1010.4 | 784.0 | 1073.2 | 692.8 |
| positive control | 5 | 425.9 ± 101.9c | 299.2 | 552.5 | 439.2 | 543.5 | 284.0 |
SD: standard deviation.
Values with the same superscript are not statistically different (P > 0.05).
Figure 1Mean and standard deviation values of fracture strenght for each group (in Newtons).