Literature DB >> 25754860

Calibration and application of an automated seepage meter for monitoring water flow across the sediment-water interface.

Tengyi Zhu1, Dafang Fu, Byron Jenkinson, Chad T Jafvert.   

Abstract

The advective flow of sediment pore water is an important parameter for understanding natural geochemical processes within lake, river, wetland, and marine sediments and also for properly designing permeable remedial sediment caps placed over contaminated sediments. Automated heat pulse seepage meters can be used to measure the vertical component of sediment pore water flow (i.e., vertical Darcy velocity); however, little information on meter calibration as a function of ambient water temperature exists in the literature. As a result, a method with associated equations for calibrating a heat pulse seepage meter as a function of ambient water temperature is fully described in this paper. Results of meter calibration over the temperature range 7.5 to 21.2 °C indicate that errors in accuracy are significant if proper temperature-dependence calibration is not performed. The proposed calibration method allows for temperature corrections to be made automatically in the field at any ambient water temperature. The significance of these corrections is discussed.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25754860     DOI: 10.1007/s10661-015-4388-7

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  7 in total

1.  Development and evaluation of an ultrasonic ground water seepage meter.

Authors:  R J Paulsen; C F Smith; D O'Rourke; T F Wong
Journal:  Ground Water       Date:  2001 Nov-Dec       Impact factor: 2.671

2.  Errors with small volume elastic seepage meter bags.

Authors:  Robert A Schincariol; John D McNeil
Journal:  Ground Water       Date:  2002 Nov-Dec       Impact factor: 2.671

3.  Use of an electromagnetic seepage meter to investigate temporal variability in lake seepage.

Authors:  Donald O Rosenberry; Roger H Morin
Journal:  Ground Water       Date:  2004 Jan-Feb       Impact factor: 2.671

4.  Evaluating ground water-sea water interactions via resistivity and seepage meters.

Authors:  Makoto Taniguchi; Tomotoshi Ishitobi; William C Burnett; Gullaya Wattayakorn
Journal:  Ground Water       Date:  2007 Nov-Dec       Impact factor: 2.671

5.  Partitioning of mono- and polycyclic aromatic hydrocarbons in a river sediment adjacent to a former manufactured gas plant site.

Authors:  Chad T Jafvert; Douglas Lane; Linda S Lee; P Suresh C Rao
Journal:  Chemosphere       Date:  2005-06-28       Impact factor: 7.086

6.  Measuring the flux at the interface of coal-tar impacted sediment and river water near a former MGP site.

Authors:  Seunghun Hyun; Chad T Jafvert; Byron Jenkinson; Carl Enfield; Brian Johnson
Journal:  Chemosphere       Date:  2007-03-26       Impact factor: 7.086

7.  PAH concentration gradients and fluxes through sand cap test cells installed in situ over river sediments containing coal tar.

Authors:  Yong Sang Kim; Leila M Nyberg; Byron Jenkinson; Chad T Jafvert
Journal:  Environ Sci Process Impacts       Date:  2013-08       Impact factor: 4.238

  7 in total
  1 in total

1.  Towards Mechanistic Hydrological Limits: A Literature Synthesis to Improve the Study of Direct Linkages between Sediment Transport and Periphyton Accrual in Gravel-Bed Rivers.

Authors:  Andrew J Neverman; Russell G Death; Ian C Fuller; Ranvir Singh; Jon N Procter
Journal:  Environ Manage       Date:  2018-06-15       Impact factor: 3.266

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.