Literature DB >> 25754243

Comparison of primary tumour volumes delineated on four-dimensional computed tomography maximum intensity projection and (18) F-fluorodeoxyglucose positron emission tomography computed tomography images of non-small cell lung cancer.

Yili Duan1, Jianbin Li1, Yingjie Zhang1, Wei Wang1, Xiaorong Sun2, Tingyong Fan1, Qian Shao1, Min Xu1, Yanluan Guo1, Dongping Shang3.   

Abstract

INTRODUCTION: The study aims to compare the positional and volumetric differences of tumour volumes based on the maximum intensity projection (MIP) of four-dimensional CT (4DCT) and (18) F-fluorodexyglucose ((18) F-FDG) positron emission tomography CT (PET/CT) images for the primary tumour of non-small cell lung cancer (NSCLC).
METHODS: Ten patients with NSCLC underwent 4DCT and (18) F-FDG PET/CT scans of the thorax on the same day. Internal gross target volumes (IGTVs) of the primary tumours were contoured on the MIP images of 4DCT to generate IGTVMIP . Gross target volumes (GTVs) based on PET (GTVPET ) were determined with nine different threshold methods using the auto-contouring function. The differences in the volume, position, matching index (MI) and degree of inclusion (DI) of the GTVPET and IGTVMIP were investigated.
RESULTS: In volume terms, GTVPET 2.0 and GTVPET 20% approximated closely to IGTVMIP with mean volume ratio of 0.93 ± 0.45 and 1.06 ± 0.43, respectively. The best MI was between IGTVMIP and GTVPET 20% (0.45 ± 0.23). The best DI of IGTVMIP in GTVPET was IGTVMIP in GTVPET 20% (0.61 ± 0.26).
CONCLUSIONS: In 3D PET images, the GTVPET contoured by standardised uptake value (SUV) 2.0 or 20% of maximal SUV (SUVmax ) approximate closely to the IGTVMIP in target size, while the spatial mismatch is apparent between them. Therefore, neither of them could replace IGTVMIP in spatial position and form. The advent of 4D PET/CT may improve the accuracy of contouring the perimeter for moving targets.
© 2015 The Royal Australian and New Zealand College of Radiologists.

Entities:  

Keywords:  fluorodeoxyglucose positron emission tomography; four-dimensional computed tomography; internal gross target volume; maximum intensity projection; non-small cell lung cancer

Mesh:

Substances:

Year:  2015        PMID: 25754243     DOI: 10.1111/1754-9485.12295

Source DB:  PubMed          Journal:  J Med Imaging Radiat Oncol        ISSN: 1754-9477            Impact factor:   1.735


  3 in total

1.  Linear accelerator-based stereotactic body radiation therapy in the treatment of oligometastatic disease.

Authors:  Hideomi Yamashita; Mami Ogita; Shuri Aoki; Osamu Abe; Keiichi Nakagawa
Journal:  Mol Clin Oncol       Date:  2020-06-09

2.  Components of the human-specific, p53-mediated "kill switch" tumor suppression mechanism are usurped by human tumors, creating the possibility of therapeutic exploitation.

Authors:  Jonathan Nyce
Journal:  Cancer Drug Resist       Date:  2019-12-19

3.  Comparison of biological target volume metrics based on FDG PET-CT and 4DCT for primary non-small-cell lung cancer.

Authors:  Yingjie Zhang; Jianbin Li; Yili Duan; Wei Wang; Fengxiang Li; Qian Shao; Min Xu
Journal:  Oncotarget       Date:  2017-07-01
  3 in total