Literature DB >> 25753785

Platelet function analyser (PFA-100) results and von Willebrand factor deficiency: a 16-year 'real-world' experience.

L Ardillon1, C Ternisien1, M Fouassier1, M Sigaud1, A Lefrançois1, M Pacault1, O Ribeyrol1, E Fressinaud1, P Boisseau1, M Trossaërt1.   

Abstract

The platelet function analyser (PFA-100) is a biological tool designed to explore primary haemostasis. This system has thus been widely demonstrated as reliable in detecting von Willebrand factor (VWF) deficiency. However, most studies were based on patients benefitting from regular medical care and accurate diagnosis, and it would seem probable that the results were somewhat optimistic, and do not reflect its performances in 'real-world' situations. We have chosen to study the reliability of PFA-100 for screening VWF ristocetin cofactor (VWF:RCo) deficiency. We retrospectively analysed the results (n = 6431) of 4027 patients referred to our centre between October 1997 and June 2013 and in whom PFA-Epi, PFA-ADP, and VWF:RCo activity had been evaluated. We studied the influence of blood group on the results and the performances of each method in a subgroup of 213 patients with genetically confirmed von Willebrand disease. We have shown that the PFA-100 system, in our experience, constitutes an excellent screening test for detecting VWF:RCo deficiency, whatever the clinical situation, in 'real-world' conditions. The negative predictive value (NPV), the positive predictive value, the sensitivity and the specificity were respectively: 0.98, 0.51, 0.98 and 0.40. When values adjusted for blood group are used, NPV and sensitivity are inferior to those using normal values which have not been adjusted for blood group. We have shown the PFA-100 method to be more efficient in screening for VWF deficiency than the VWF:RCo technique.
© 2015 John Wiley & Sons Ltd.

Entities:  

Keywords:  platelet function analyser-100; ristocetin cofactor activity; von Willebrand factor

Mesh:

Substances:

Year:  2015        PMID: 25753785     DOI: 10.1111/hae.12653

Source DB:  PubMed          Journal:  Haemophilia        ISSN: 1351-8216            Impact factor:   4.287


  6 in total

Review 1.  Point of care whole blood microfluidics for detecting and managing thrombotic and bleeding risks.

Authors:  Scott L Diamond; Jason M Rossi
Journal:  Lab Chip       Date:  2021-09-28       Impact factor: 7.517

2.  Variables that Influence Platelet Function Analyzer-100™ Closure Times in Healthy Algerian Adults.

Authors:  Malika Belkacemi; Yassine Merad
Journal:  Int J Appl Basic Med Res       Date:  2021-07-19

Review 3.  Rare forms of von Willebrand disease.

Authors:  Emmanuel J Favaloro
Journal:  Ann Transl Med       Date:  2018-09

Review 4.  Platelet Mechanobiology Inspired Microdevices: From Hematological Function Tests to Disease and Drug Screening.

Authors:  Yingqi Zhang; Fengtao Jiang; Yunfeng Chen; Lining Arnold Ju
Journal:  Front Pharmacol       Date:  2022-01-20       Impact factor: 5.988

5.  Multiparameter platelet function analysis of bleeding patients with a prolonged platelet function analyser closure time.

Authors:  Floor C J I Heubel-Moenen; Sanne L N Brouns; Linda Herfs; Lara S Boerenkamp; Natalie J Jooss; Rick J H Wetzels; Paul W M Verhezen; Patric Machiels; Karyn Megy; Kate Downes; Johan W M Heemskerk; Erik A M Beckers; Yvonne M C Henskens
Journal:  Br J Haematol       Date:  2022-01-10       Impact factor: 8.615

6.  Harmonizing platelet function analyzer testing and reporting in a large laboratory network.

Authors:  Emmanuel J Favaloro; Soma Mohammed; Ronny Vong; Kent Chapman; Geoffrey Kershaw; Sarah Just; Lynne Connelly; Michael Ryan; Diane Zebeljan; Timothy Brighton; Leonardo Pasalic
Journal:  Int J Lab Hematol       Date:  2022-06-26       Impact factor: 3.450

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.