| Literature DB >> 25752201 |
Aaron Lloyd1, Vinay Pasupuleti1, Priyaleela Thota1, Chaitanya Pant2, David D K Rolston3, Adrian V Hernandez4, Vicente A Benites-Zapata5, Thomas G Fraser6, Curtis J Donskey7, Abhishek Deshpande8.
Abstract
Loop-mediated isothermal DNA amplification (LAMP) is currently used as standalone diagnostic test for C. difficile infection (CDI). We assessed the diagnostic accuracy of LAMP for the diagnosis of CDI. We searched 5 databases to identify studies that compared LAMP with culture cytotoxicity neutralization assay or anaerobic toxigenic culture (TC) of C. difficile. We used the random-effects model to calculate pooled sensitivities, specificities, diagnostic odds ratios, and their 95% confidence intervals (CIs). The search of the databases yielded 16 studies (6979 samples) that met inclusion criteria. When TC was used as the gold standard (6572 samples), bivariate analysis yielded a mean sensitivity of 0.95 (95% CI, 0.93-0.97; I(2)=67.4) and a mean specificity of 0.99 (95% CI, 0.96-1.00; I(2)=97.0). LAMP is a useful diagnostic tool with high sensitivity and specificity for detecting CDI. The results should, however, be interpreted only in the presence of clinical suspicion and symptoms of CDI.Entities:
Keywords: C. difficile; CDI; Diagnostic accuracy; LAMP; Sensitivity; Specificity
Mesh:
Year: 2015 PMID: 25752201 DOI: 10.1016/j.diagmicrobio.2015.02.007
Source DB: PubMed Journal: Diagn Microbiol Infect Dis ISSN: 0732-8893 Impact factor: 2.803