Literature DB >> 25751835

Corneal topographic astigmatism (CorT) to quantify total corneal astigmatism.

Noel Alpins, James K Y Ong, George Stamatelatos.   

Abstract

PURPOSE: To evaluate the performance of corneal topographic astigmatism (CorT) based on total corneal power measurements.
METHODS: Anterior, posterior, and total corneal power measurements of 526 virgin eyes obtained using the CSO Sirius tomographer (Costuzione Strumenti Oftalmici, Scandicci, Florence, Italy) were analyzed. Individual CorTs were created from each set of data. These CorTs were assessed using ocular residual astigmatism (ORA), which quantifies corneo-refractive differences. A low standard deviation of the ocular residual astigmatism (ORAsd) indicates a low variability between corneal astigmatism and refractive cylinder. A low mean of the ORA magnitude indicates a close correlation of refractive cylinder and corneal astigmatism.
RESULTS: The CorT based on total corneal power measurements had an ORAsd of 0.30 diopters (D) and a mean ORA magnitude of 0.53 D. The CorT candidates based on anterior corneal power measurements all had an ORAsd of at least 0.32 D, and the mean ORA magnitudes were all 0.64 D or greater. Both the ORAsd and mean ORA magnitude of the CorT based on total corneal power measurements were significantly less than those of the CorT based on anterior corneal power measurements (both P < .001, as estimated via bootstrapping).
CONCLUSIONS: The CorT based on total corneal power measurements corresponds better, both in variability and closeness, with manifest refractive cylinder than the CorT based on anterior corneal power measurements. This total CorT would be fundamental when planning toric intraocular lenses or limbal relaxing incisions or other corneal astigmatic surgery. Copyright 2015, SLACK Incorporated.

Entities:  

Mesh:

Year:  2015        PMID: 25751835     DOI: 10.3928/1081597X-20150224-02

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  3 in total

1.  Corneal Topographic versus Manifest Refractive Astigmatism in Patients with Keratoconus: A Retrospective Cross-Sectional Study.

Authors:  Mohamed Elkadim; Mohamed H Nasef; Ahmed Roshdy Alagorie; Waleed A Allam
Journal:  Clin Ophthalmol       Date:  2022-06-20

2.  Hemidivisional vector planning to reduce and regularize irregular astigmatism by laser treatment.

Authors:  Noel Alpins; James K Y Ong; George Stamatelatos
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2022-03-09       Impact factor: 3.535

3.  Posterior corneal astigmatism: a review article.

Authors:  Seyed-Farzad Mohammadi; Masoud Khorrami-Nejad; Moein Hamidirad
Journal:  Clin Optom (Auckl)       Date:  2019-08-12