Literature DB >> 25751148

Correction: bioimpedance spectroscopy for assessment of volume status in patients before and after general anaesthesia.

.   

Abstract

Entities:  

Year:  2015        PMID: 25751148      PMCID: PMC4353726          DOI: 10.1371/journal.pone.0117956

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.240


× No keyword cloud information.
There are errors in the “Results” section in the Abstract of the published article. Duration of anesthesia should read 154 ± 69 minutes, and the value for perioperative urinary excretion should read 0.3 ± 0.2 L. The headings for Table 3 are misaligned. Please view the correct Table 3 here.
Table 3

Association between net perioperative fluid balance and changes in pre- to postoperative extracellular volume, with multiple levels of adjustments.

Model 1: net perioperative fluid balance Model 2: + serum albumin Model 3: + age Model 4: + body mass index Model 5: + serum creatinine Model 6: + preoperative fluid therapy Model 7: + preoperative blood pressure Model 8: + preoperative capillary leak index Model 9: + postoperative capillary leak index
Outcome variable: Delta ECV
r2 0.6460.6460.6490.6520.6570.6780.6790.6810.713
p-value1 for each model <0.001 <0.001 <0.001 <0.001 <0.001 <0.001 <0.001 <0.001 <0.001
p-value2 for individual predictors <0.001 0.8450.4790.4350.330 0.046 0.6390.540 0.011
Beta 0.804 0.014−0.0560.060−0.077 −0.152 −0.049−0.065 0.202

Multiple regression analysis: After stepwise adjustment the coefficients of determination (r2), the p-value1 for the combined effect of all predictors for each model, the p-value2 for the individual effect of a predictor and the correlation coefficient (Beta) represent the association between the outcome and the predictor variables. Boldface indicating statistical significance (p<0.05).

Multiple regression analysis: After stepwise adjustment the coefficients of determination (r2), the p-value1 for the combined effect of all predictors for each model, the p-value2 for the individual effect of a predictor and the correlation coefficient (Beta) represent the association between the outcome and the predictor variables. Boldface indicating statistical significance (p<0.05).
  1 in total

1.  Bioimpedance spectroscopy for assessment of volume status in patients before and after general anaesthesia.

Authors:  Matthäus Ernstbrunner; Lisa Kostner; Oliver Kimberger; Peter Wabel; Marcus Säemann; Klaus Markstaller; Edith Fleischmann; Barbara Kabon; Manfred Hecking
Journal:  PLoS One       Date:  2014-10-31       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.