Transseptal puncture from the jugular vein and balloon cryoablation for atrial fibrillation in a patient with azygos continuation of an interrupted inferior vena cava.

Artur Baszko1, Piotr Kałmucki2, Rafał Dankowski2, Magdalena Łanocha3, Tomasz Siminiak2, Andrzej Szyszka2.   

Abstract

AIMS: Inferior vena cava (IVC) interruption is a rare anatomic variant where the azygos vein (AV) drains the blood from the IVC to the upper part of the right atrium via the superior vena cava. Here, we report balloon cryoablation of the pulmonary veins (PVs) via superior access in a patient with atrial fibrillation. METHODS AND
RESULTS: After the first failed ablation attempt due to IVC interruption, balloon cryoablation with a 28-mm Arctic Front Advance cryoballoon (Medtronic CryoCath LP, Quebec, Canada) via superior access was performed; it requires only a single transseptal puncture (TP), and the patient had optimal PV anatomy. Deflectable electrodes were inserted into the right ventricle and coronary sinus from the right femoral vein. The right internal jugular vein was accessed using an SL0 transseptal sheath and BRK needle. The TP was performed under transoesophageal echocardiographic guidance with a Safe Sept wire because the septum was stiff. All PVs were engaged: the left using an ablation catheter before balloon insertion and the inferior following a 'push-up' technique because of a leak above the veins. Cryothermal energy was delivered after checking for occlusion. The procedure lasted 210 min, fluoroscopy time was 78 min, and air-kerma dose was 194 mGy. During the 6-month follow-up, no episodes of atrial fibrillation were detected on several Holter recordings.
CONCLUSIONS: Successful PV isolation in patients with AV continuation of an interrupted IVC can be safely performed using superior access with balloon cryoablation, after several modifications of standard equipment. Published on behalf of the European Society of Cardiology. All rights reserved.
© The Author 2015. For permissions please email: journals.permissions@oup.com.

Entities:  

Keywords:  Atrial fibrillation; Azygos vein; Balloon cryoablation; Transseptal puncture

Mesh:

Year:  2015        PMID: 25750216     DOI: 10.1093/europace/euu413

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  4 in total

1.  Cryoballoon ablation from above, through a prosthetic patch atrial septal defect repair.

Authors:  John L Fitzgerald; Austin N May; Ehsan Mahmoodi; James Leitch; Haris M Haqqani; Nicholas Jackson
Journal:  HeartRhythm Case Rep       Date:  2020-03-21

2.  Characteristics of anatomical difficulty for cryoballoon ablation: insights from CT.

Authors:  Takahiro Hayashi; Masato Murakami; Shigeru Saito; Kiyotaka Iwasaki
Journal:  Open Heart       Date:  2022-01

3.  Ordinary AV Nodal Reentry Tachycardia-Unusual Ablation: A Case Report and Review of the Literature.

Authors:  Franz Haertel; P Christian Schulze; Anett Große; Dirk Prochnau; Ralf Surber
Journal:  Case Rep Cardiol       Date:  2022-08-23

4.  Systematic review of electrophysiology procedures in patients with obstruction of the inferior vena cava.

Authors:  Ali Al-Sinan; Kim H Chan; Glenn D Young; Andrew Martin; Ali Sepahpour; Raymond W Sy
Journal:  J Cardiovasc Electrophysiol       Date:  2022-04-30       Impact factor: 2.942

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.